Opitimization on F.P.I. process and procedure for signaling lead pipe of anti-asthmatic presure
摘 要
某机防喘压力信号管荧光渗透检测过程中,零件尚未进行任何加工时,常发生不同单位之间的检测结论不一致的现象。为解决此问题,采用理论和工艺试验相结合的方法,对产生结论不一致的原因进行了分析,并依据原因制定了合理而有效的解决方法。
Abstract
During the fluorescent penetrant inspection of signaling lead pipe of anti-asthmatic pressure, different F.P.I results for the parts can often be presented among the different production departments even the parts to be inspected have not been undertaken any procession. This paper aims to solve the above-mentioned problems and to analyze the reason of such different results by combining theoretical study with process examination. Some reasonable and effective methods based on the reason analysis were deduced.
中图分类号 V232.4 TG115.28 DOI 10.11973/wsjc202004015
所属栏目 实践经验
基金项目
收稿日期 2019/11/24
修改稿日期
网络出版日期
作者单位点击查看
联系人作者徐亚亚(xyyluck@163.com)
备注徐亚亚(1976-),女,本科,高级工程师,主要从事航空发动机机件无损检测工作
引用该论文: XU Yaya,LIU Xingyong,XU Jian,ZHANG Ming. Opitimization on F.P.I. process and procedure for signaling lead pipe of anti-asthmatic presure[J]. Nondestructive Testing, 2020, 42(4): 69~71
徐亚亚,刘兴勇,徐健,张明. 防喘压力信号引接管荧光渗透检测工序及工艺优化[J]. 无损检测, 2020, 42(4): 69~71