Cause analysis of parallel linear magnetic traces on a bolt forging
摘 要
某螺栓锻件磁粉检测时发现磁痕显示,通过金相观察、能谱分析及X射线衍射分析等试验后确认,该磁痕为原材料微观偏析组织导致材料磁导率出现差异而形成的非相关显示。
Abstract
The magnetic traces were observed on a bolt forging during magnetic particle testing. The magnetic traces were analyzed by metallographic observation, energy spectrum analysis and X-ray diffraction analysis. The magnetic traces were non-relevant indication of the magnetic permeability difference of the material caused by the microsegregation of the raw material.
中图分类号 TG115.28 DOI 10.11973/wsjc202006010
所属栏目 试验研究
基金项目
收稿日期 2019/9/25
修改稿日期
网络出版日期
作者单位点击查看
备注李志浩(1986-),男,硕士,主要从事特种设备、铸锻件产品无损检测技术工作
引用该论文: LI Zhihao,ZHU Xiaofeng. Cause analysis of parallel linear magnetic traces on a bolt forging[J]. Nondestructive Testing, 2020, 42(6): 47~49
李志浩,朱晓锋. 某螺栓锻件表面平行线状磁痕显示原因分析[J]. 无损检测, 2020, 42(6): 47~49
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】朱永辉,李晔.锻件表面磁痕分析[J].机械制造,2010,48(546):70-71.
【2】宋志哲.磁粉检测[M].北京:中国劳动社会保障出版社,2007.
【3】程建云.锻件磁粉检测缺陷性质的分析[J].无损检测,2007,29(10):613-614.
【2】宋志哲.磁粉检测[M].北京:中国劳动社会保障出版社,2007.
【3】程建云.锻件磁粉检测缺陷性质的分析[J].无损检测,2007,29(10):613-614.