在某600MW发电机组大修过程中,发现汽轮机低压缸的叶片和隔板发生了腐蚀。从腐蚀形貌,腐蚀产物成分和工作情况等不同方面进行了分析,发现该汽轮机产生腐蚀的原因为氯离子腐蚀,并提出了相应的防范措施。
Abstract
During the overhaul of a 600MW generator unit, corrosion was found in the blades and baffles of a low-pressure cylinder of steam turbine. It was found that the corrosion of the steam turbine was caused by chloride ion corrosion through analyzing the corrosion morphology, corrosion product composition and working conditions. And some corresponding measures were proposed to prevent the corrosion.