Cause of Leakage on HR3C Stainless Steel Final Superheater Tube of Boiler
摘 要
某超超临界锅炉末级过热器管发生泄漏事故,通过宏观观察、化学成分分析、力学性能试验、金相检验和能谱分析等方法,对过热器管的泄漏原因进行了分析。结果表明:HR3C不锈钢末级过热器管材料中存在晶间氧化和原始内折叠缺陷,采用水浸法超声波检测未检出,运行过程中在缺陷部位产生应力集中并萌生裂纹源,裂纹在轧制过程中的交变应力作用下沿缺陷扩展最终造成管壁泄漏。
Abstract
The final superheater tube of an ultra supercritical boiler leaked. The causes of leakage on superheater tube were analyzed by means of macro observation, chemical composition analysis, mechanical property test, metallographic examination and energy spectrum analysis. The results show that there were intergranular oxidation and original inner fold defects in the material of HR3C stainless steel final superheater tube, which were not detected by water immersion ultrasonic detection. During operation, stress concentration and crack source generated at the defect, and the crack propagated along the defect under the action of alternating stress during rolling, finally resulted in tube wall leakage.
中图分类号 TG142.73 DOI 10.11973/lhjy-wl202105012
所属栏目 质量控制与失效分析
基金项目
收稿日期 2020/5/14
修改稿日期
网络出版日期
作者单位点击查看
备注殷小双(1992-),男,助理工程师,主要从事电站锅炉压力容器检验及金属材料失效分析工作,1176686618@qq.com
引用该论文: YIN Xiaoshuang,SHEN Kang,LIU Changfu,DU Shuangming,DONG Shuqing. Cause of Leakage on HR3C Stainless Steel Final Superheater Tube of Boiler[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2021, 57(5): 50~53
殷小双,谌康,刘长福,杜双明,董树青. 锅炉HR3C不锈钢末级过热器管泄漏原因[J]. 理化检验-物理分册, 2021, 57(5): 50~53
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】晏嘉陵. 600 MW超临界电站锅炉末级过热器管爆裂失效分析[J]. 理化检验(物理分册),2017,53(6):445-448.
【2】蒙新明,张路,赖云亭,等. 某超临界机组锅炉过热器管爆管原因分析[J]. 理化检验(物理分册),2015,51(5):353-357.
【3】肖国华,李益民,王理博. 超超临界机组锅炉末级过热器爆管原因分析[J]. 理化检验(物理分册),2011,47(4):245-247.
【4】杨有文. 火电厂高温再热器SA-213TP310HCBN(HR3C)管材爆管技术管理探讨[J]. 中国设备工程,2017(24):153-154.
【5】秦承鹏,王亮,李梁,等. 超超临界1000 MW机组锅炉末级再热器爆管原因分析[J]. 热力发电,2012,41(10):69-72.
【6】牟春华,杨征,赵新宝,等. 超超临界锅炉用HR3C耐热钢的研究进展[J]. 热加工工艺,2018,47(2):23-27.
【7】李新梅,张忠文,杜宝帅,等. 高温服役5万h后HR3C钢的显微组织和力学性能[J]. 机械工程材料,2019,43(8):51-54.
【8】张忠文,李新梅,魏玉忠,等. HR3C钢焊接接头的组织和性能研究[J]. 热加工工艺,2008,37(23):5-8.
【9】吕一楠,刘树涛,张红军. HR3C钢内压蠕变试验后显微组织与力学性能试验研究[J]. 动力工程学报,2013,33(10):822-828.
【10】包福全,邵立强. 热轧无缝钢管质量缺陷与检测方法探讨[J]. 中国金属通报,2018(6):252.
【11】付乃民,高建学,王庆伟. 厚壁无缝钢管晶间裂纹缺陷分析[J]. 天津冶金,2019(5):40-42.
【12】武晶晶,李荣,苏丽凤,等. 冷拔20钢管内表面缺陷分析[J]. 世界有色金属,2016(19):33-34.
【13】宫志民,梁建山,田青超. 无缝钢管典型内折叠缺陷分析[J]. 轧钢,2014,31(6):31-33.
【14】辛曜明. 热轧无缝钢管的质量缺陷界定问题[J]. 中国金属通报,2016(1):11-12.
【2】蒙新明,张路,赖云亭,等. 某超临界机组锅炉过热器管爆管原因分析[J]. 理化检验(物理分册),2015,51(5):353-357.
【3】肖国华,李益民,王理博. 超超临界机组锅炉末级过热器爆管原因分析[J]. 理化检验(物理分册),2011,47(4):245-247.
【4】杨有文. 火电厂高温再热器SA-213TP310HCBN(HR3C)管材爆管技术管理探讨[J]. 中国设备工程,2017(24):153-154.
【5】秦承鹏,王亮,李梁,等. 超超临界1000 MW机组锅炉末级再热器爆管原因分析[J]. 热力发电,2012,41(10):69-72.
【6】牟春华,杨征,赵新宝,等. 超超临界锅炉用HR3C耐热钢的研究进展[J]. 热加工工艺,2018,47(2):23-27.
【7】李新梅,张忠文,杜宝帅,等. 高温服役5万h后HR3C钢的显微组织和力学性能[J]. 机械工程材料,2019,43(8):51-54.
【8】张忠文,李新梅,魏玉忠,等. HR3C钢焊接接头的组织和性能研究[J]. 热加工工艺,2008,37(23):5-8.
【9】吕一楠,刘树涛,张红军. HR3C钢内压蠕变试验后显微组织与力学性能试验研究[J]. 动力工程学报,2013,33(10):822-828.
【10】包福全,邵立强. 热轧无缝钢管质量缺陷与检测方法探讨[J]. 中国金属通报,2018(6):252.
【11】付乃民,高建学,王庆伟. 厚壁无缝钢管晶间裂纹缺陷分析[J]. 天津冶金,2019(5):40-42.
【12】武晶晶,李荣,苏丽凤,等. 冷拔20钢管内表面缺陷分析[J]. 世界有色金属,2016(19):33-34.
【13】宫志民,梁建山,田青超. 无缝钢管典型内折叠缺陷分析[J]. 轧钢,2014,31(6):31-33.
【14】辛曜明. 热轧无缝钢管的质量缺陷界定问题[J]. 中国金属通报,2016(1):11-12.
相关信息