Detection and Analysis of AC-DC Mixed Interference to Gas Pipeline
摘 要
详细分析和评价了地铁引起的直流杂散电流、高压输电线路和高速铁路引起的交流杂散电流对无锡燃气管道的干扰影响。结果表明:采用国内标准对直流干扰进行评价过于严格,可采用澳大利亚AS 2832.1-2015标准进行评价;采用国内外相关标准对交/直流混合干扰进行评价均不太准确,需要管道从业者进一步研究。
Abstract
The interference effects of DC stray currents caused by subways, AC stray currents caused by high-voltage transmission lines and high-speed railways on Wuxi gas pipelines were analyzed and evaluated in detail. The results show that the domestic standard is too strict in the evaluation of DC interference, so the Australian AS 2832.1-2015 standard can be used for evaluation. It is not accurate using domestic and foreign relevant standards to evaluate AC/DC mixed interference. And pipeline practitioners need to do further study.