Control of unrelated fluorescence indication of build-up edge
摘 要
针对零件在机加工后,其圆角根部产生的积屑、积屑瘤等导致材料表面缝隙变得紧密,引起非相关荧光显示,易造成缺陷漏检的问题,通过对实际检测案例的分析,找出机械加工积屑瘤引起荧光痕迹显示的原因,并采用相关处理措施,避免了该类问题的发生。
Abstract
Aiming at the problems of the accumulation of chips and build-up on the root of the fillet after the components were machined,which causes the gaps on the surface of the material to become tight and irrelevant fluorescents display, and easily leaded to missing inspection of defects.In this article,an experimental analysis on existing inspection case was conducted and the causes leading to the fluorescent trace indication of machining build-up edge were found out,and some relevant treatment measures were taken to avoid such problems.
中图分类号 TG115.28 DOI 10.11973/wsjc202201012
所属栏目 实践经验
基金项目
收稿日期 2021/4/6
修改稿日期
网络出版日期
作者单位点击查看
备注王乃翠(1985-),女,高级工程师,主要从事航空发动机零部件的机械加工及渗透检测工作
引用该论文: WANG Naicui,YANG Xuebing,WAN Lei,TANG Jianchao,LI Xueting. Control of unrelated fluorescence indication of build-up edge[J]. Nondestructive Testing, 2022, 44(1): 53~55
王乃翠,杨学兵,万磊,唐建朝,李雪婷. 积屑瘤非相关荧光显示的控制[J]. 无损检测, 2022, 44(1): 53~55