Eddy current testing of tubesheet area of heat exchanger tubes
摘 要
针对常规涡流Bobbin检测技术的局限性,开展了热交换器换热管管板区内壁的补充涡流检测,确定了涡流三混频检测技术和阵列检测技术的检测灵敏度,并对3种技术的检测结果进行了综合对比。
Abstract
In view of the limitations of conventional eddy current Bobbin testing technology, the supplementary eddy current testing of the inner wall of the tubesheet area of the heat exchanger tube is carried out, the detection sensitivity of triple frequency mixing testing technology and array testing technology is determined, and the detection results of the three technologies are comprehensively compared.
中图分类号 TG115.28 DOI 10.11973/wsjc202203007
所属栏目 试验与研究
基金项目
收稿日期 2021/8/19
修改稿日期
网络出版日期
作者单位点击查看
联系人作者冯俊(297154546@qq.com)
备注冯俊(1982-),男,工程师,主要从事核设备的涡流检测和相关技术工作
引用该论文: FENG Jun,ZENG Yuhua,CHEN Chuan,FENG Sheng. Eddy current testing of tubesheet area of heat exchanger tubes[J]. Nondestructive Testing, 2022, 44(3): 32~35
冯俊,曾玉华,陈川,冯盛. 热交换器换热管管板区的涡流检测[J]. 无损检测, 2022, 44(3): 32~35
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】任吉林,林俊明,徐可北.涡流检测[M].北京:机械工业出版社,2013.
【2】杨崇安.蒸汽发生器传热管旋转探头与阵列探头涡流检测技术对比[J].无损检测,2017,39(4):64-66,71.
【3】冯俊,王波,祁攀.热交换器换热管内壁涡流检测显示判定方法[J].无损检测,2017,39(9):43-48.
【4】陈霞,韩捷,王蓉,等.不同类型电涡流探头对核电站传热管胀管过渡段缺陷的定位准确性研究[J].机械与电子,2016,34(4):29-31,35.
【2】杨崇安.蒸汽发生器传热管旋转探头与阵列探头涡流检测技术对比[J].无损检测,2017,39(4):64-66,71.
【3】冯俊,王波,祁攀.热交换器换热管内壁涡流检测显示判定方法[J].无损检测,2017,39(9):43-48.
【4】陈霞,韩捷,王蓉,等.不同类型电涡流探头对核电站传热管胀管过渡段缺陷的定位准确性研究[J].机械与电子,2016,34(4):29-31,35.