Corrosion Behavior of T2 Copper in Simulated In-Situ Leaching Solution Environment
摘 要
针对某采用地浸液为低温热源的水源热泵蒸发器铜管的穿孔问题,在模拟地浸液中对T2铜开展了全浸腐蚀试验(模拟腐蚀和加速腐蚀),通过试样的宏观和微观表面形貌,腐蚀速率和极化曲线等分析了T2铜的腐蚀行为。结果表明:地浸液中所含Cl-对T2铜的腐蚀具有促进作用,供氧差异导致缺氧区域形成严重局部腐蚀,T2铜不宜作为地浸液的换热材料。
Abstract
Aiming at the perforation problem of copper tube in an evaporator of a water source heat pump unit using in-situ leaching solution as a low-temperature heat source, full immersion corrosion tests (simulating corrosion and accelerated corrosion) were carried out to T2 copper in simulated in-situ leaching solution. The corrosion behavior of T2 copper was analyzed by macroscopic and microscopic surface morphology, corrosion rates and polarization curves of the samples. The results show that Cl- in the in-situ leaching solution had a promotion effect on the corrosion of T2 copper, and the difference in oxygen supply led to severe localized corrosion in the hypoxic area. So T2 copper should not be used as heat transfer material for in-situ leaching solution.
中图分类号 TG172.5 DOI 10.11973/fsyfh-202203008
所属栏目 试验研究
基金项目
收稿日期 2020/5/11
修改稿日期
网络出版日期
作者单位点击查看
引用该论文: CAO Yongkai,XIAO Kui. Corrosion Behavior of T2 Copper in Simulated In-Situ Leaching Solution Environment[J]. Corrosion & Protection, 2022, 43(3): 47
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】杜艳芳,郑欣,郑亚楠,等. 金属铜在不同环境下的腐蚀研究[J]. 材料保护,2016,49(S1):81-83.
【2】田梦然,郑艺华,吴荣华. 水源热泵用换热设备常用金属的腐蚀性能[J]. 化工进展,2015,34(12):4391-4397.
【3】符策鹄,任海滔,姚华,等. 曝晒位置对纯铜热带海洋大气环境腐蚀性能的影响研究[J]. 装备环境工程,2017,14(6):116-121.
【4】林玉珍,杨德钧. 腐蚀和腐蚀控制原理[M]. 2版.北京:中国石化出版社,2014:8-9.
【5】左禹,熊金平. 工程材料及其耐腐蚀性[M]. 北京:中国石化出版社,2013:125.
【2】田梦然,郑艺华,吴荣华. 水源热泵用换热设备常用金属的腐蚀性能[J]. 化工进展,2015,34(12):4391-4397.
【3】符策鹄,任海滔,姚华,等. 曝晒位置对纯铜热带海洋大气环境腐蚀性能的影响研究[J]. 装备环境工程,2017,14(6):116-121.
【4】林玉珍,杨德钧. 腐蚀和腐蚀控制原理[M]. 2版.北京:中国石化出版社,2014:8-9.
【5】左禹,熊金平. 工程材料及其耐腐蚀性[M]. 北京:中国石化出版社,2013:125.
相关信息