某沿海变电站HGIS套管接线端子镀银层腐蚀剥落的原因
          
Reasons for Corrosion and Exfoliation of Silver Coating on Bushing Wiring Board of HGIS in a Coastal Substation

摘    要
某沿海变电站66 kV复合式气体绝缘金属封闭开关(HGIS)套管接线端子一侧的镀银层出现大面积腐蚀剥落现象。采用宏观形貌观察、化学成分分析、金相检验和扫描电镜等试验方法,结合服役地区大气环境数据对镀银层失效原因进行了研究分析。结果表明:起泡及剥离的镀银层已发生氧化或者硫化,暴露出来的铝合金基材已被氧化;腐蚀介质通过镀银层表面凹坑、划痕或界面孔隙等通道进入镀层与基体界面是导致接线端子镀银层腐蚀脱落的主要原因。
标    签 腐蚀   镀银层   接线端子   变电站   corrosion   silver coating   wiring board   substation  
 
Abstract
The silver coating on one side of bushing wiring board of 66kV hybrid gas insulated switchgear (HGIS) in a coastal substation corroded and exfoliated in a large area. The failure reasons of the silver coating were studied by means of macroscopic morphology observation, chemical composition analysis, metallographic examination and scanning electron microscopy, combined with atmospheric environment data in service area. The results indicated that the blistered and exfoliated silver coating was oxidized or vulcanized, and the exposed substrate was also oxidized. The corrosive mediators entered the interface between the aluminum alloy substrate and silver coating through the pits, scratches or interfacial gaps on the surface of silver coating, which was the main reason for the corrosion and exfoliation of the silver coating on the wiring board.

中图分类号 TB304   DOI 10.11973/fsyfh-202205012

 
  中国光学期刊网论文下载说明


所属栏目 失效分析

基金项目

收稿日期 2020/7/22

修改稿日期

网络出版日期

作者单位点击查看


引用该论文: WANG Tianpeng,NIE Xiaobo,SUN Mingcheng,WANG Yunan. Reasons for Corrosion and Exfoliation of Silver Coating on Bushing Wiring Board of HGIS in a Coastal Substation[J]. Corrosion & Protection, 2022, 43(5): 68


论文评价
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
分享论文
分享到新浪微博 分享到腾讯微博 分享到人人网 分享到 Google Reader 分享到百度搜藏分享到Twitter

参考文献
【1】GALY C,LE GUEN E,LACOSTE E,et al. Main defects observed in aluminum alloy parts produced by SLM:from causes to consequences[J]. Additive Manufacturing,2018,22:165-175.
 
【2】WANG Y,YANG Z W,ZHANG L X,et al. Low-temperature diffusion brazing of actively metallized Al2O3 ceramic tube and 5A05 aluminum alloy[J]. Materials&Design,2015,86:328-337.
 
【3】王平,周慧波,刘强.金属镀层大气腐蚀性[J].腐蚀与防护,2013,34(10):926-928.
 
【4】郝留成,廉继英,周瑛,等. 6063铝合金材料镀银层脱落原因及其解决途径[J].铸造技术,2009,30(10):1350-1352.
 
【5】李晓征,王斌,王战辉,等.一例T6热处理不当引起的6063铝合金镀银层结合力不良的故障分析[J].电镀与涂饰,2019,38(21):1175-1178.
 
【6】肖凯,梁永纯,董重里. GIS绝缘盆导体镀银层脱落失效分析[J].广东电力,2013,26(2):103-105.
 
【7】胡加瑞,刘纯,谢亿,等.高压开关设备镀银缺陷分析[J].电镀与涂饰,2013,32(10):23-25.
 
【8】庞先海,甄利,贾志辉,等.高压隔离开关过热缺陷分析及防范措施[J].河北电力技术,2015,34(5):46-49.
 
【9】张宝根,周泰华,汝永平,等.镀银件腐蚀变色及保护[J].电镀与涂饰,1998,17(4):30-33.
 
【10】李玉涛. GB/T3190-2008《变形铝及铝合金化学成分》国家新标准牌号情况[J].有色金属加工,2009,38(2):20-21.
 
【11】郝文魁,杨丙坤,马光,等.沿海工业环境下6A02铝合金接线板的腐蚀行为[J].机械工程材料,2017,41(12):59-63.
 
【12】XU Y,LI Y,ZHENG L J,et al. Site selection of wind farms using GIS and multi-criteria decision making method in Wafangdian,China[J]. Energy,2020,207:118222.
 
【13】赵杨.大气污染物排放量预测及其环境承载力分析——以瓦房店市为例[J].环境与发展,2017,29(10):42,49.
 
【14】高蒙,孙志华,刘明,等.固体颗粒沉积对7B04铝合金初期大气腐蚀行为的影响[J].装备环境工程,2016,13(5):160-165.
 
【15】郭孟秋,蔡健平,刘明,等.无机盐沉积下7B04铝合金表面微液滴形成研究[J].航空材料学报,2010,30(4):48-52.
 
【16】POPE D,GIBBENS H R,MOSS R L. The tarnishing of Ag at naturally-occurring H2S and SO2 levels[J]. Corrosion Science,1968,8(12):883-887.
 
相关信息
   标题 相关频次
 变电站接地材料的电解腐蚀
 4
 变电站铝合金接线板失效分析
 4
 变电站内杂散电流对接地网腐蚀的影响
 4
 变电站设备铝及铝合金材料的大气腐蚀及选材
 4
 变电站接地网存在的问题及改造措施
 3
 海南电网变电站金属架构防护涂层的使用情况
 3
 沿海工业环境下6A02铝合金接线板的腐蚀行为
 3
 Φ219mm×10.5mm弯管环焊缝穿孔失效分析
 2
 1 000 MPa级超高强度热镀锌钢板耐腐蚀性能
 2
 1050A铝合金模拟海洋大气环境腐蚀行为的中性盐雾试验
 2
 1050A铝合金在模拟海洋大气环境中周浸腐蚀行为
 2
 10号碳钢在NaOH溶液中的腐蚀电化学行为
 2
 12Cr1MoV钢在碱金属硫氯盐中的腐蚀行为
 2
 12Cr-F/M钢在超临界水中的腐蚀行为
 2
 13Cr不锈钢与Ni基合金油管表面擦划伤的腐蚀行为
 2
 14Cr1MoR钢在高温硫环境中的失效行为
 2
 16MnR钢在多种回填材料中的腐蚀行为
 2
 16Mn钢在管输俄罗斯原油析出水中的腐蚀行为
 2
 201型不锈钢在酸性食物模拟环境中的腐蚀行为
 2
 20CrMnTi钢在海洋环境中的腐蚀行为
 2
 20G/316L双金属复合管失效的原因
 2
 20G无缝钢管开裂原因
 2
 20号钢在HCl-H2S-H2O溶液中的腐蚀行为
 2
 20号钢在气田站场分离器积液中的腐蚀行为
 2
 220kV钢芯铝绞线断股事故化学分析
 2
 22MnB5热冲压淬火零件的耐腐蚀性能
 2
 2507双相不锈钢钾盐蒸发罐腐蚀的原因分析
 2
 2A12铝合金当量加速腐蚀试验
 2
 2-甲基咪唑啉及其复配缓蚀剂在高硬度电解质水溶液中的缓蚀性能
 2
 304H弹簧钢丝及弹簧表面腐蚀的原因
 2