Detection and Evaluation of AC Corrosion of Buried Steel Pipeline
摘 要
通过现场交直流干扰参数的测试对珠江支线埋地钢质管道的受干扰情况进行了评价,结果表明,该段管道受到严重的交直流混合干扰。使用交流电压参数与交流电流密度参数评价管道的受干扰情况,会得到截然不同的评价结论。阴极保护带来的阴极极化对防腐蚀层破损点周边的局部电阻率有明显的影响。在低电阻率、高极化水平下,可能出现管道的交流电压很低但是交流电流密度很大的现象。
Abstract
The interference condition of the buried steel pipeline of the Pearl River Branch Pipeline was evaluated by the on site AC and DC interference parameters test. The results showed that the pipeline was subject to serious AC and DC mixed interference. Using AC voltage parameters and AC current density parameters to evaluate the interference of the pipeline, we would get completely different evaluation conclusions. Cathodic polarization caused by cathodic protection had obvious influence on localized resistivity around the damage point of anti-corrosion coating. Under low resistivity and high polarization condition, the AC voltage of the pipeline might be very low but the AC current density might be very high.
中图分类号 TG174 DOI 10.11973/fsyfh-202301016
所属栏目 应用技术
基金项目
收稿日期 2021/3/11
修改稿日期
网络出版日期
作者单位点击查看
引用该论文: LIU Xinling,WANG Chunyu,LIANG Qiang,DAI Jun,WANG Jue. Detection and Evaluation of AC Corrosion of Buried Steel Pipeline[J]. Corrosion & Protection, 2023, 44(1): 88
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】张玉星,杜艳霞,姜子涛. 交流干扰对埋地管线阴极保护的影响[J]. 腐蚀与防护,2013,(4):350-354.
【2】吴广春,杜艳霞,路民旭,等. 埋地管道交流干扰缓解技术研究现状[J]. 腐蚀科学与防护技术. 2014,26(5):464-468.
【3】梁毅,杜艳霞. 交流干扰和阴极保护协同作用下的腐蚀评判标准与机理研究进展[J]. 中国腐蚀与防护学报. 2020,40(3):215-222.
【4】BUCHLER M. Alternating current corrosion of cathodically protected pipelines:Discussion of the involved processes and their consequences on the critical interference values[J]. Materials & Corrosion,2012,63(12):1181-1187.
【5】TANG D Z,DU Y X,LU M X,et al. Effect of AC current on corrosion behavior of cathodically protected Q235 steel[J]. Materials & Corrosion,2015,66(3):278-285.
【6】张平,向波,龚树鸣,等. 埋地钢质管道交流干扰防护技术标准:GB/T 50698-2011[S]. 北京:中国计划出版社,2011.
【7】TANG D Z, DU Y X. Study on CP criteria for mild steel in the presence of AC interference[C]//Corrosion 2014,[S.l.]:NACE International,2014.
【2】吴广春,杜艳霞,路民旭,等. 埋地管道交流干扰缓解技术研究现状[J]. 腐蚀科学与防护技术. 2014,26(5):464-468.
【3】梁毅,杜艳霞. 交流干扰和阴极保护协同作用下的腐蚀评判标准与机理研究进展[J]. 中国腐蚀与防护学报. 2020,40(3):215-222.
【4】BUCHLER M. Alternating current corrosion of cathodically protected pipelines:Discussion of the involved processes and their consequences on the critical interference values[J]. Materials & Corrosion,2012,63(12):1181-1187.
【5】TANG D Z,DU Y X,LU M X,et al. Effect of AC current on corrosion behavior of cathodically protected Q235 steel[J]. Materials & Corrosion,2015,66(3):278-285.
【6】张平,向波,龚树鸣,等. 埋地钢质管道交流干扰防护技术标准:GB/T 50698-2011[S]. 北京:中国计划出版社,2011.
【7】TANG D Z, DU Y X. Study on CP criteria for mild steel in the presence of AC interference[C]//Corrosion 2014,[S.l.]:NACE International,2014.
相关信息