Corrosion Causes of Distillation and Crystallization System in Nitrochlorobenzene Plant and Countermeasures
摘 要
硝基氯苯装置经常因腐蚀问题导致非计划停工,尤其是精馏和结晶系统,腐蚀问题最为突出,严重影响装置的长周期安全稳定运行。在现场工艺物料分析的基础上,通过水解试验和热解试验模拟工艺过程,明确了精馏和结晶系统的腐蚀介质来源;通过实验室腐蚀模拟试验和现场腐蚀挂片试验,研究结晶器工艺侧、循环水侧和液环真空泵的腐蚀规律。同时,提出了相应的防腐蚀措施,解决了硝基氯苯装置长期存在的腐蚀问题。
Abstract
Corrosion problems often lead to unplanned shutdown of nitrochlorobenzene plants, especially in distillation and crystallization systems, which seriously affect the safe and stable operation of the plant for a long period. Based on the analysis of process materials in field, the sources of corrosive media in distillation and crystallization system were identified by hydrolysis and pyrolysis tests. The corrosion rules of process side and circulating water side of crystallizer and the corrosion rules of liquid ring vacuum pump were studied through corrosion simulation tests in laboratory and corrosion coupon tests in field. At the same time, the corresponding anti-corrosion measures were proposed to solve the long-term corrosion problem of nitrochlorobenzene plant.
中图分类号 TG172 DOI 10.11973/fsyfh-202302017
所属栏目 失效分析
基金项目
收稿日期 2021/2/8
修改稿日期
网络出版日期
作者单位点击查看
引用该论文: LIU Xiwu. Corrosion Causes of Distillation and Crystallization System in Nitrochlorobenzene Plant and Countermeasures[J]. Corrosion & Protection, 2023, 44(2): 101
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】姚银春. 硝基氯苯生产中下脚低油精馏塔的设计[J]. 氯碱工业, 2017, 53(4):30-33, 42.
【2】季浩, 顾奇龙, 刘梅. 气相色谱法测定2, 4-二硝基氯苯及其有机杂质[J]. 染料与染色, 2017, 54(6):49-51.
【3】徐益. 对硝基氯苯变色原因分析及防腐体系的建立[J]. 能源化工, 2020, 41(3):75-80.
【4】贾建功. 硝基氯苯结晶器的腐蚀与防护[J]. 河南化工, 2004, 21(11):46-47.
【5】周本省. 工业冷却水系统中金属的腐蚀与防护[M]. 北京:化学工业出版社, 1993.
【6】薛安海, 郎国江. 循环水冷却器腐蚀原因分析[J]. 齐鲁石油化工, 2012, 40(4):334-338.
【7】LOTO R, JOSEPH O, AKANJI O. Electrochemical corrosion behaviour of austenitic stainless steel (type 304) in dilute hydrochloric acid solution[J]. Journal of Materials and Environmental Science, 2015, 6(9):2409-2417.
【8】ZHANG B, WANG J, WU B, et al. Unmasking chloride attack on the passive film of metals[J]. Nature Communications, 2018, 9:2559.
【9】STREHBLOW H H. Passivity of metals studied by surface analytical methods, a review[J]. Electrochimica Acta, 2016, 212:630-648.
【2】季浩, 顾奇龙, 刘梅. 气相色谱法测定2, 4-二硝基氯苯及其有机杂质[J]. 染料与染色, 2017, 54(6):49-51.
【3】徐益. 对硝基氯苯变色原因分析及防腐体系的建立[J]. 能源化工, 2020, 41(3):75-80.
【4】贾建功. 硝基氯苯结晶器的腐蚀与防护[J]. 河南化工, 2004, 21(11):46-47.
【5】周本省. 工业冷却水系统中金属的腐蚀与防护[M]. 北京:化学工业出版社, 1993.
【6】薛安海, 郎国江. 循环水冷却器腐蚀原因分析[J]. 齐鲁石油化工, 2012, 40(4):334-338.
【7】LOTO R, JOSEPH O, AKANJI O. Electrochemical corrosion behaviour of austenitic stainless steel (type 304) in dilute hydrochloric acid solution[J]. Journal of Materials and Environmental Science, 2015, 6(9):2409-2417.
【8】ZHANG B, WANG J, WU B, et al. Unmasking chloride attack on the passive film of metals[J]. Nature Communications, 2018, 9:2559.
【9】STREHBLOW H H. Passivity of metals studied by surface analytical methods, a review[J]. Electrochimica Acta, 2016, 212:630-648.
相关信息