Influence Factors of Coupon Instant-Off Testing Method under Dynamic DC Stray Current Interference
摘 要
通过现场试验研究了试片埋设时间、断电延迟时间、试片埋设深度、外部干扰电场以及参比电极位置等因素对试片断电法测试结果的影响,通过对比不同条件下的测试结果,获得不同因素的影响规律。结果表明:试片的裸露面积越大,达到稳定极化状态所需的时间越长,浅埋试片需要更长的时间才能达到稳定的极化状态;对于试片瞬时断电电位的测试,应设置合理的断电延迟时间;在当前试验条件下,试片极化稳定所需要的时间最长为25 h,150 ms的断电延迟时间是合理的;土壤中流动的电流会在试片和参比电极之间产生地电位梯度,影响试片断电电位的正确读数,可以通过缩小试片和参比电极之间的距离来消减外电场产生的误差。
Abstract
Through field test, the influence of factors such as test piece embedding time, instant-off delay time, coupon buried depth, external interference electric field and reference electrode position on the test results of coupon instant-off method was studied. By comparing the test results under different conditions, the influence laws of different factors were obtained. The results showed that the larger the exposed area of the coupon, the longer it took to reach a stable polarization state, and the longer the shallow buried coupon took to reach a stable polarization state. For the test of the instantaneous instant-off potential of the coupon, a reasonable instant-off delay time should be set . Under the current test conditions, the longest time required for the polarization stability of the coupon was 25 h, and the instant-off delay time of 150 ms was reasonable. The current flowing in the soil would generate a ground potential gradient between the coupon and the reference electrode, which would affect the correct reading of the instant-off potential of the coupon. The error caused by the external electric field could be reduced by reducing the distance between the coupon and the reference electrode.
中图分类号 TG174 DOI 10.11973/fsyfh-202306005
所属栏目 试验研究
基金项目 国家重点研发计划专项项目(2016YFC0802103);北京市博士后科研活动经费资助(2022A062)
收稿日期 2021/4/16
修改稿日期
网络出版日期
作者单位点击查看
引用该论文: QIN Huimin,ZHANG Tao,DU Yanxia,CHE Kun,LU Minxu. Influence Factors of Coupon Instant-Off Testing Method under Dynamic DC Stray Current Interference[J]. Corrosion & Protection, 2023, 44(6): 24
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】ALLAHKARAM S R,ISAKHANI-ZAKARIA M,DERAKHSHANI M,et al.Investigation on corrosion rate and a novel corrosion criterion for gas pipelines affected by dynamic stray current[J].Journal of Natural Gas Science and Engineering,2015,26:453-460.
【2】钱建华,闫永贵,李威力.城市轨道交通杂散电流对埋地管线腐蚀的影响[J].腐蚀科学与防护技术,2009,21(3):250-251.
【3】CHEN Z G,QIN C K,TANG J X,et al.Experiment research of dynamic stray current interference on buried gas pipeline from urban rail transit[J].Journal of Natural Gas Science and Engineering,2013,15:76-81.
【4】刘杰,杜艳霞,覃慧敏,等.地铁杂散电流对埋地管道的干扰规律[J].腐蚀与防护,2019,40(1):43-47,70.
【5】刘瑶,谭松玲,邢琳琳,等.北京埋地燃气管道地铁杂散电流干扰影响现场检测及规律分析[J].腐蚀科学与防护技术,2019,31(4):429-435.
【6】朱祥剑,杜艳霞,覃慧敏,等.地铁杂散电流干扰下埋地管道管地电位动态波动规律[J].腐蚀与防护,2019,40(12):878-885.
【7】姜有文,刘猛,赵建涛,等.检查片法在阴极保护评价中的问题分析[J].管道技术与设备,2016(5):45-47.
【8】国家能源局.埋地钢质检查片应用技术规范:SY/T 0029—2012[S].北京:石油工业出版社,2012.
【9】NEKOKSA G.Flat cathodic protection test probe:US6060877[P].2000-05-09.
【10】RIEMER D P,ORAZEM M E.Application of boundary element models to predict effectiveness of coupons for accessing cathodic protection of buried structures[J].CORROSION,2000,56(8):794-800.
【11】张丰,齐晓忠,金宏,等.试片断电法在管道阴极保护中的应用[J].油气储运,2013,32(7):760-763.
【12】徐华天,杜艳霞,路民旭,等.极化探头测试埋地管道阴极保护电位的新方法[J].腐蚀科学与防护技术,2013,25(3):238-241.
【13】黄腾飞.埋地管道阴极保护电位参数及电位测试技术研究[D].成都:西南石油学院,2004.
【2】钱建华,闫永贵,李威力.城市轨道交通杂散电流对埋地管线腐蚀的影响[J].腐蚀科学与防护技术,2009,21(3):250-251.
【3】CHEN Z G,QIN C K,TANG J X,et al.Experiment research of dynamic stray current interference on buried gas pipeline from urban rail transit[J].Journal of Natural Gas Science and Engineering,2013,15:76-81.
【4】刘杰,杜艳霞,覃慧敏,等.地铁杂散电流对埋地管道的干扰规律[J].腐蚀与防护,2019,40(1):43-47,70.
【5】刘瑶,谭松玲,邢琳琳,等.北京埋地燃气管道地铁杂散电流干扰影响现场检测及规律分析[J].腐蚀科学与防护技术,2019,31(4):429-435.
【6】朱祥剑,杜艳霞,覃慧敏,等.地铁杂散电流干扰下埋地管道管地电位动态波动规律[J].腐蚀与防护,2019,40(12):878-885.
【7】姜有文,刘猛,赵建涛,等.检查片法在阴极保护评价中的问题分析[J].管道技术与设备,2016(5):45-47.
【8】国家能源局.埋地钢质检查片应用技术规范:SY/T 0029—2012[S].北京:石油工业出版社,2012.
【9】NEKOKSA G.Flat cathodic protection test probe:US6060877[P].2000-05-09.
【10】RIEMER D P,ORAZEM M E.Application of boundary element models to predict effectiveness of coupons for accessing cathodic protection of buried structures[J].CORROSION,2000,56(8):794-800.
【11】张丰,齐晓忠,金宏,等.试片断电法在管道阴极保护中的应用[J].油气储运,2013,32(7):760-763.
【12】徐华天,杜艳霞,路民旭,等.极化探头测试埋地管道阴极保护电位的新方法[J].腐蚀科学与防护技术,2013,25(3):238-241.
【13】黄腾飞.埋地管道阴极保护电位参数及电位测试技术研究[D].成都:西南石油学院,2004.
相关信息