Causes of large area corrosion of ND steel for low temperature economizer
摘 要
某电厂低温省煤器ND钢发生大面积腐蚀,采用宏观观察、化学成分分析、金相检验、硬度测试、扫描电镜分析、X射线衍射分析、离子色谱分析等方法研究腐蚀原因。结果表明:试样的化学成分、显微组织、显微硬度等均符合标准要求;泄漏的水溶解了烟气中的硫化物,形成酸性溶液并吸附到管子外表面,溶解的F-、Cl-和SO2-4破坏了ND钢管壁表面的保护膜,导致低温省煤器发生大面积腐蚀。最后提出了改进建议,以避免低温省煤器ND钢发生大范围腐蚀。
Abstract
A large area of corrosion occurred in ND steel of low temperature economizer in a power plant. The causes of corrosion were studied by means of macroscopic observation, chemical composition analysis, metallographic examination, hardness test, scanning electron microscope analysis, X-ray diffraction analysis and ion chromatography analysis. The results show that the chemical composition, microstructure and microhardness of the samples all met the requirements of the standard. The leaked water dissolved the sulfide in the flue gas to form an acidic solution, which was adsorbed to the outer surface of the pipe. The dissolved F-, Cl-and SO2-4 destroyed the protective film on the surface of the ND steel pipe wall, resulting in large-scale corrosion of the low-temperature economizer. Finally, suggestions for improvement were put forward to avoid large-scale corrosion of ND steel in low-temperature economizer.
中图分类号 TG142.3 TG115.2 DOI 10.11973/lhjy-wl202308012
所属栏目 质量控制与失效分析
基金项目
收稿日期 2022/8/7
修改稿日期
网络出版日期
作者单位点击查看
备注张安文(1988-),男,博士,主要从事理化检验工作,awzhang13s@alum.imr.ac.cn
引用该论文: ZHANG Anwen,HUO Yan,LI Jianxiong,ZHANG Zhibo. Causes of large area corrosion of ND steel for low temperature economizer[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2023, 59(8): 47~50
张安文,霍岩,李建雄,张志博. 低温省煤器ND钢大面积腐蚀原因[J]. 理化检验-物理分册, 2023, 59(8): 47~50
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】韩中合,李鹏.锅炉加装低温省煤器热经济性分析[J].热力发电,2016,45(6):70-73,80.
【2】刘鹤忠,连正权.低温省煤器在火力发电厂中的运用探讨[J].电力勘测设计,2010(4):32-38.
【3】王加勇,杨茉,陈伟,等.考虑多因素两级低温省煤器经济性能分析[J].节能技术,2017,35(3):225-228,234.
【4】于凯,邴一萌,徐琳, 等.某电厂低温省煤器泄漏问题分析[J].锅炉制造, 2020(6):20-26.
【5】许适群.关于露点腐蚀及用钢的综述[J].石油化工腐蚀与防护,2000,17(1):1-4,65.
【6】王东明,陈培旺.煤粉锅炉烟气脱硝改造后低温省煤器腐蚀原因分析及措施[J].冶金动力,2020,39(4):47-48,52.
【7】蔡昊.09CrCuSb钢在锅炉制造中的应用[J].工业锅炉,2005(5):22-25.
【8】叶先祥,周成,张聪.新型耐硫酸盐酸露点腐蚀钢的性能研究[J].腐蚀科学与防护技术,2015,27(2):135-140.
【9】郑文龙.新型耐硫酸露点用钢──ND钢[J].机械工程材料,1996,20(3):46.
【10】常季,陈吉,崔霄.ND钢耐低温露点腐蚀性能的研究[J].石油化工腐蚀与防护, 2016, 33(1):8-11.
【2】刘鹤忠,连正权.低温省煤器在火力发电厂中的运用探讨[J].电力勘测设计,2010(4):32-38.
【3】王加勇,杨茉,陈伟,等.考虑多因素两级低温省煤器经济性能分析[J].节能技术,2017,35(3):225-228,234.
【4】于凯,邴一萌,徐琳, 等.某电厂低温省煤器泄漏问题分析[J].锅炉制造, 2020(6):20-26.
【5】许适群.关于露点腐蚀及用钢的综述[J].石油化工腐蚀与防护,2000,17(1):1-4,65.
【6】王东明,陈培旺.煤粉锅炉烟气脱硝改造后低温省煤器腐蚀原因分析及措施[J].冶金动力,2020,39(4):47-48,52.
【7】蔡昊.09CrCuSb钢在锅炉制造中的应用[J].工业锅炉,2005(5):22-25.
【8】叶先祥,周成,张聪.新型耐硫酸盐酸露点腐蚀钢的性能研究[J].腐蚀科学与防护技术,2015,27(2):135-140.
【9】郑文龙.新型耐硫酸露点用钢──ND钢[J].机械工程材料,1996,20(3):46.
【10】常季,陈吉,崔霄.ND钢耐低温露点腐蚀性能的研究[J].石油化工腐蚀与防护, 2016, 33(1):8-11.
相关信息