Control Measures on Substation Noise Characteristics and Noise Reduction Technology
摘 要
目前变电站噪声对周边环境的影响愈发明显,并已成为亟待解决的环境问题。通过对厦门站噪声特性的测试分析,确定了噪声的主要传播途径,通过针对性降噪措施的实施,利用开发的声全息技术可以快速准确地识别配电站、变配电设备的噪声源。通过对噪声源及传播路径的改善,可有效降低变配电设备的噪声量级。
Abstract
Current transformer noise influences on surrounding environment more and more obvious, and has become a pressing environmental problems. Determined by the test and analysis the characteristics of the xiamen station noise, noise is the main route of transmission, and introduces a series of corresponding noise reduction measures. Noise sources can be quickly and accurately identified to the distribution station and power distribution equipments.using acoustic holography technology. The improvement of noise source and propagation path can effectively reduce the noise level variable power distribution equipment.
中图分类号 TB535.1
所属栏目 成果与经验
基金项目
收稿日期 2014/6/25
修改稿日期
网络出版日期
作者单位点击查看
备注邵宇鹰(1977-),男,博士研究生,从事输变电设备状态检测及减震降噪方面研究。
引用该论文: Shao Yuying,Zhang Siping. Control Measures on Substation Noise Characteristics and Noise Reduction Technology[J]. Power & Energy, 2014, 35(4): 542~544
邵宇鹰,张思平. 变电站噪声特性及降噪控制措施[J]. 电力与能源, 2014, 35(4): 542~544
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】吕敬友,黄玉,池爱平.变电站噪声对环境的影响与防治措施[J].电力与能源,2011,32(2):162-164.
【2】董志刚.变压器的噪声[J].变压器.1995,(11):27-31.
【3】李亚晶.变压器的噪声及控制措施[C].2007年云南电力装备制造业振兴与创新论坛论文集,2008.
【4】乔静.户内变电站主变压器降噪和通风分析[J].电力环境保护,2006,22(3):49-51.
【5】陈秋,李振海.变电站噪声防治方案研究[J].城市建设理论研究,2011(23):78-81.
【6】周建国,李莉华.变电站、换流站和输电线路噪声及其治理技术[J].中国电力,2009,42(3):75-78.
【2】董志刚.变压器的噪声[J].变压器.1995,(11):27-31.
【3】李亚晶.变压器的噪声及控制措施[C].2007年云南电力装备制造业振兴与创新论坛论文集,2008.
【4】乔静.户内变电站主变压器降噪和通风分析[J].电力环境保护,2006,22(3):49-51.
【5】陈秋,李振海.变电站噪声防治方案研究[J].城市建设理论研究,2011(23):78-81.
【6】周建国,李莉华.变电站、换流站和输电线路噪声及其治理技术[J].中国电力,2009,42(3):75-78.
相关信息