Protection Agents during Lay-up of Air-cooled Condensers
摘 要
针对空冷凝汽器运行条件及空冷机组的停用保护适应性, 设计了保护剂的性能评价试验装置及方法。通过研究保护剂的耐蚀性和保护膜的电化学阻抗谱, 获得了两种保护效果良好的直接空冷机组停用保护剂及最佳使用量, 且保护剂对凝汽器树脂的性能没有显著影响。
Abstract
A performance evaluation device of protective agents was designed based on operation and lay-up conditions of air-cooled condensers (ACCs). The anti-corrosion performance of protection agents were tested by electrochemical impedance spectroscopy. Two kinds of protection agents for lay-up of air-cooled condensers and the optimum contents were obtained. The two protection agents were harmless to ion exchange resin performance.
中图分类号 TG174.42
所属栏目 应用技术
基金项目 华能集团重点科技项目(HNKJ12-H28)
收稿日期 2013/1/13
修改稿日期
网络出版日期
作者单位点击查看
备注邓宇强(1974-),高级工程师,硕士,从事火力发电厂防腐防垢研究工作,
引用该论文: DENG Yu-qiang,CAO Jie-yu,ZHANG Xiang-jin,NI Rui-tao,QI Dong-dong,SONG Fei,ZHANG Hong-bo,LIU Feng. Protection Agents during Lay-up of Air-cooled Condensers[J]. Corrosion & Protection, 2014, 35(1): 87
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】BARRY Dooley R,DENIS Aspden J,ANDREW G Howell,et al. Assessing and controlling corrosion in air-cooled condensers[J]. Power Plant Chemistry,2009,5:264-274.
【2】邓宇强, 林卫丽, 张祥金,等. 空冷凝汽器的腐蚀与防护[J]. 腐蚀与防护, 2012, 33(2): 160-162.
【3】葛红花, 周国定, 廖强强. 发电厂停炉保护用十八烷基胺的成膜研究[J]. 腐蚀与防护, 1999, 20(3): 118-120.
【4】朱志平, 王丽英. 十八胺对阴树脂的污染及对策[J].热力发电, 2001,2: 57-58.
【5】丁醒如, 闻人勤, 龚云峰,等. 大机组十八胺停运保护中凝结水处理系统树脂污染问题研究[J]. 热力发电, 2004,7: 64-67.
【2】邓宇强, 林卫丽, 张祥金,等. 空冷凝汽器的腐蚀与防护[J]. 腐蚀与防护, 2012, 33(2): 160-162.
【3】葛红花, 周国定, 廖强强. 发电厂停炉保护用十八烷基胺的成膜研究[J]. 腐蚀与防护, 1999, 20(3): 118-120.
【4】朱志平, 王丽英. 十八胺对阴树脂的污染及对策[J].热力发电, 2001,2: 57-58.
【5】丁醒如, 闻人勤, 龚云峰,等. 大机组十八胺停运保护中凝结水处理系统树脂污染问题研究[J]. 热力发电, 2004,7: 64-67.
相关信息