Application of the Industrial CT Technology in the Ammunition Charge Density Difference Measurement
摘 要
采用两种方法对现有BT-400型工业CT无损检测系统进行了密度分辨率指标测定,得出该系统的密度分辨率为1.0%左右,并使用BT-400型CT设备对某战斗部装药完成了密度差测量,测量结果与这批样品开壳弹排水法结果进行了比较,装药密度测量误差小于1%,密度差测量结果在量值上一致。说明工业CT技术密度差测量方法可行、测量结果可信,具有一定参考意义。
Abstract
This paper introduces two kinds of methods for the testing of the density resolution of the BT-400 type industrial CT nondestructive testing system. The density resolution of the system is about 1.0%, and the measurement of one warhead charging density difference is completed by the industrial Ct equipment. The results and the sample open shell drainage method results are compared. The charge density error is less than 1%, the density difference is consistent in magnitude. It shows that the density difference measurement method is feasible by industrial CT technology, the measurement results are reliable. It has some reference significance to the reader.
中图分类号 TG115.28,TJ410.3+4
所属栏目 试验研究
基金项目
收稿日期 2013/5/13
修改稿日期
网络出版日期
作者单位点击查看
备注高玉玲(1966-),女,高级工程师,主要从事工业CT无损检测、环境性能试验等测试技术研究。
引用该论文: GAO Yu-ling,RUI Rui,SONG Li-jun,ZHANG Jing,LI Feng,ZHANG Feng,HU Dong-chang. Application of the Industrial CT Technology in the Ammunition Charge Density Difference Measurement[J]. Nondestructive Testing, 2014, 36(4): 14~19
高玉玲,瑞睿,宋丽君,张晶,李凤,张峰,胡东常. 工业CT技术在弹药装药密度差测量中的应用[J]. 无损检测, 2014, 36(4): 14~19
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】刘力,张英平.用工业CT测量物质密度的ASTM标准方法[J].无损检测, 2006,28(6): 324-326.
【2】GJB 5311—2004工业CT系统性能测试方法[S].
【3】杨文海,何德昌,徐军培,等.γ射线工业CT技术在高能炸药密度检测中的应用[J].火炸药学报,2001(3):33-34,72.
【4】倪培君,蔡和平,张维国,等.非均匀结构材料密度工业CT定量检测方法[J].无损检测,2012,34(2):11-15,44.
【5】GJB 5312—2004工业射线层析成像(CT)检测[S].
【2】GJB 5311—2004工业CT系统性能测试方法[S].
【3】杨文海,何德昌,徐军培,等.γ射线工业CT技术在高能炸药密度检测中的应用[J].火炸药学报,2001(3):33-34,72.
【4】倪培君,蔡和平,张维国,等.非均匀结构材料密度工业CT定量检测方法[J].无损检测,2012,34(2):11-15,44.
【5】GJB 5312—2004工业射线层析成像(CT)检测[S].
相关信息