摘 要
针对在常压储罐底板漏磁检测过程中遇到的刮擦、搭接、腐蚀与对接焊缝等典型信号,根据实际经验以及图形显示提出了使用FloormapVS2i软件进行分析的方法和对干扰数据进行删除及调整显示门槛的应对措施,提高了漏磁检测结果的准确性,可以为常压储罐的漏磁检测提供参考。
Abstract
For typical signals obtained by the tank bottom leakage detection process, such as scratching, lap joint, corrosion and butt welding, based on the practical experience and graphic display, analysis method of using FloormapVS2i software and the counter measures for deleting interference data and adjusting the display response threshold were presented to improve the accuracy of the result of magnetic flux leakage testing. The above mentioned measures can provide the reference for the magnetic flux leakage detection of atmospheric storage tank.
中图分类号 TG115.28
所属栏目 试验研究
基金项目 黑龙江省普通高等学校化工过程机械重点实验室开放课题资助项目(hj201310)
收稿日期 2013/5/3
修改稿日期
网络出版日期
作者单位点击查看
备注王亚东(1978-),男,高级工程师,API653检验师,容器检验师,管道检验师,AEⅢ,ETⅢ,主要从事常压储罐检验检测、漏测检测技术、声发射检测技术的研究与应用工作。
引用该论文: WANG Ya-dong,WANG Xiang,XU Yan-ting,XU Jie-le,ZHENG Jian-yong. The Signal Analysis of Magnetic Flux-leakage Examination for Bottom Plate of Atmospheric Storage Tank[J]. Nondestructive Testing, 2014, 36(4): 23~25
王亚东,王翔,徐彦廷,许皆乐,郑建勇. 常压储罐底板漏磁检测的信号分析[J]. 无损检测, 2014, 36(4): 23~25
被引情况:
【1】胡西洋,沈功田,卢超,刘德宇, "漏磁检测仪检测通道一致性评价试验",无损检测 37, 26-29(2015)
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】刘力,张英平.用工业CT测量物质密度的ASTM标准方法[J].无损检测, 2006,28(6): 324-326.
【2】GJB 5311—2004工业CT系统性能测试方法[S].
【3】杨文海,何德昌,徐军培,等.γ射线工业CT技术在高能炸药密度检测中的应用[J].火炸药学报,2001(3):33-34,72.
【4】倪培君,蔡和平,张维国,等.非均匀结构材料密度工业CT定量检测方法[J].无损检测,2012,34(2):11-15,44.
【5】GJB 5312—2004工业射线层析成像(CT)检测[S].
【2】GJB 5311—2004工业CT系统性能测试方法[S].
【3】杨文海,何德昌,徐军培,等.γ射线工业CT技术在高能炸药密度检测中的应用[J].火炸药学报,2001(3):33-34,72.
【4】倪培君,蔡和平,张维国,等.非均匀结构材料密度工业CT定量检测方法[J].无损检测,2012,34(2):11-15,44.
【5】GJB 5312—2004工业射线层析成像(CT)检测[S].
相关信息