X-ray Detection of the Fillet Weld of Tube-Tube Sheet in Shell and Tube Heat Exchanger
摘 要
通过使用192Ir探伤机小焦点放射源, 利用拥有专利自主知识产权的自制曝光头装置将放射源由源机中送出, 经过补偿块中心圆柱孔定位器到达管中既定位置, 采用向后透照的方式进行检测, 从而实现管子-管板的角焊缝检测成像, 保证了换热器管子-管板角焊缝的品质, 在透照室外进行检测操作, 减少了探伤操作人员的辐射剂量。
Abstract
Testing of the tube and tube sheet fillet weld was realized by using 192Ir source with small focus. The source was sent to the required location through the central cylindrical hole locator by self-made exposure head device. The test was carried out using backward transillumination manner and the image of the fillet weld could be obtained. The test could ensure the quality of tube-tube sheet fillet weld of heat exchanger and the risk of the operators subjected with radiation dose was greatly reduced because the test was carried in outdoors.
中图分类号 TG115.28
所属栏目 2014远东无损检测新技术论坛论文精选
基金项目
收稿日期 2014/6/25
修改稿日期
网络出版日期
作者单位点击查看
备注毛幼平(1963-), 男, 工程师, 主要从事压力容器质量管理工作。
引用该论文: MAO You-ping,ZHEN Bin-hu,WANG Tao,XU Jian. X-ray Detection of the Fillet Weld of Tube-Tube Sheet in Shell and Tube Heat Exchanger[J]. Nondestructive Testing, 2014, 36(12): 33~35
毛幼平,郑兵虎,王涛,徐健. 列管式换热器的管子-管板角焊缝射线检测[J]. 无损检测, 2014, 36(12): 33~35
被引情况:
【1】王勇,吴凯,陈海英,肖俊, "一种辨别暗袋曝光的方法",无损检测 37, 82-83(2015)
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】GB/T 3323—2005 金属熔化焊焊接接头射线照相 [S].
【2】ASME锅炉及压力容器规范国际性规范[S].
【2】ASME锅炉及压力容器规范国际性规范[S].