ICP-AES Determination of Silicon and Phosphorus in Ferroaluminum Manganese Alloy
摘 要
采用电感耦合等离子体原子发射光谱法测定铝锰铁中硅、磷的含量。选择178.242 nm和251.611 nm作为磷、硅的分析谱线,可消除谱线的重叠干扰。使用与分析样品基体相接近的标准样品和相同的测定条件,可克服物理干扰,并比较了酸、碱熔样方式对待测元素的影响。本法已应用于铝锰铁样品中硅、磷的测定,对照试验测定结果的相对标准偏差(n=6)不大于7.0%。
Abstract
ICP-AES was used to determine silicon and phosphorous in ferroaluminun manganese alloy. Wavelengths of 178.242 nm and 251.611 nm were used as the analytic lines for silicon and phosphorous, which could eliminate overlapping interference of spectral line. The physical interferences were eliminated by using standard sample similar to the matrixes of the analytes at the same experimental conditions. Meanwhile, the effects of the acid or basic solvents were compared. The method was used in the determination of silicon and phosphorous in ferroaluminum manganese alloy. The RSD (n=6) of controlled trials was not more than 7.0%.
中图分类号 O657.31
所属栏目 工作简报
基金项目
收稿日期 2013/12/9
修改稿日期
网络出版日期
作者单位点击查看
备注耿新(1967-),男,江苏江阴人,副教授,博士,主要研究方向为无机材料制备与分析。
引用该论文: GENG Xin,CHEN Ke-zhong,SUN Peng,DOU Cheng,ZHU Xiao-ming. ICP-AES Determination of Silicon and Phosphorus in Ferroaluminum Manganese Alloy[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2015, 51(1): 43~45
耿新,陈克仲,孙鹏,窦成,朱晓明. 电感耦合等离子体原子发射光谱法测定铝锰铁中硅和磷[J]. 理化检验-化学分册, 2015, 51(1): 43~45
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】商英,尹艳清,殷雪霞,等.电感耦合等离子体原子发射光谱法测定钛铁中钛、铝、硅、磷、铜和锰[J].理化检验-化学分册, 2013,49(2):193-195.
【2】朱海丰.电感耦合等离子体原子发射光谱法测定锰铁中微量磷[J].理化检验-化学分册, 2009,45(1):10-12.
【3】唐华应,方艳,薛秀萍.电感耦合等离子体原子发射光谱法测定锰铁合金中铬硅磷[J].冶金分析, 2007,27(9):48-50.
【4】邵海舟,刘成花.电感耦合等离子体原子发射光谱法测定铌铁中铌钛钽硅铝磷[J].冶金分析, 2011,31(12):54-57.
【5】赵容超,李海平,杨大蔚,等.微波消解-电感耦合等离子体发射光谱法测定锰铁中磷镍铜钛钒[J].冶金分析, 2012,32(6):60-63.
【2】朱海丰.电感耦合等离子体原子发射光谱法测定锰铁中微量磷[J].理化检验-化学分册, 2009,45(1):10-12.
【3】唐华应,方艳,薛秀萍.电感耦合等离子体原子发射光谱法测定锰铁合金中铬硅磷[J].冶金分析, 2007,27(9):48-50.
【4】邵海舟,刘成花.电感耦合等离子体原子发射光谱法测定铌铁中铌钛钽硅铝磷[J].冶金分析, 2011,31(12):54-57.
【5】赵容超,李海平,杨大蔚,等.微波消解-电感耦合等离子体发射光谱法测定锰铁中磷镍铜钛钒[J].冶金分析, 2012,32(6):60-63.
相关信息