ICP-AES Determination of Pb, Cd, Cr, Hg, Sb, As, Se, Ba and Ni Stripped from Metal Decorations
摘 要
金属饰品样品用硝酸(20+80)溶液浸泡过夜,采用电感耦合等离子体原子发射光谱法测定金属饰品中铅、镉、铬、汞、锑、砷、硒、钡和镍的溶出量。选择波长为216.9,228.8,267.7,194.2,206.8,189.0,196.0,455.4,216.6 nm的9条谱线依次作为测定铅、镉、铬、汞、锑、砷、硒、钡和镍的分析线。铅、镉、铬、锑、砷、硒、钡和镍的质量浓度与其发射强度在10.0 mg·L-1以内、汞在2.0 mg·L-1以内呈线性关系,检出限(3s)在0.002~0.05 mg·L-1之间。方法用于金属饰品的分析,回收率在95.4%~103.0%之间,测定值的相对标准偏差(n=11)在0.68%~2.0%之间。
Abstract
Sample of metal decoration was immersed in HNO3-H2O (20+80) solution for 24 h, and the contents of Pb, Cd, Cr, Hg, Sb, As, Se, Ba and Ni in sample solution were determined by ICP-AES. Wavelengths of 216.9, 228.8, 267.7, 194.2, 206.8, 189.0, 196.0, 455.4 and 216.6 nm were selected as analytical lines for the determination of the 9 elements respectively. Linear relationships between values of emission intensity of Cd, Cr, Se, Ba and Ni were found in the ranges within 10.0 mg·L-1, and within 2.0 mg·L-1 for Hg. Values of detection limit (3s) of the method found were in the range of 0.002-0.05 mg·L-1. The proposed method was used in the analysis of metal decorations, giving values of recovery and RSD′s (n=11) in the ranges of 95.4%-103.0% and 0.68%-2.0% respectively.
中图分类号 O657.31
所属栏目
基金项目 浙江省质量技术监督局科研计划资助项目(20080240)
收稿日期 2011/1/5
修改稿日期
网络出版日期
作者单位点击查看
备注陈德文(1978-),男,土家族,湖北利川人,高级工程师,博士,主要从事化学检验工作。
引用该论文: CHEN De-wen,WANG Huan-huang,LIU Kang-wei,ZHU Hong-xing. ICP-AES Determination of Pb, Cd, Cr, Hg, Sb, As, Se, Ba and Ni Stripped from Metal Decorations[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2012, 48(2): 150~151
陈德文,汪欢晃,刘康伟,朱红星. 电感耦合等离子体原子发射光谱法测定金属饰品中铅、镉、铬、汞、锑、砷、硒、钡、镍溶出量[J]. 理化检验-化学分册, 2012, 48(2): 150~151
被引情况:
【1】高永刚,叶曦雯,牛增元,张艳艳,李引, "金属服装附件及仿真饰品中镍的快速比色检测法",理化检验-化学分册 49, 1196-1198(2013)
【2】侯艳芳,周桂友, "石墨炉原子吸收光谱法测定陶瓷饰品中铅、镉、铬和钴的溶出量",理化检验-化学分册 50, 1461-1463(2014)