GC Determination of Hexane, Acetone, Butanone and Butyl Acetate in Air of Workplace
摘 要
用气相色谱法对空气中正己烷、丙酮、丁酮和乙酸丁酯的含量进行测定。采用活性炭管采集了空气中的正己烷、丙酮、丁酮和乙酸丁酯,采用二硫化碳进行解吸,用Agilent 19091N-216 HP-INNOWAX Polyethylene Glycol毛细管色谱柱分离,氢焰离子化检测器检测。正己烷、丙酮、丁酮和乙酸丁酯的检出限(3S/N)为0.43,0.30,0.44,1.7 mg·L-1。方法的解吸率在86.7%~100.3%之间,相对标准偏差(n=6)在1.97%~3.89%之间。
Abstract
The contents of hexane, acetone, 2-butanone and butyl acetate in air of workplace were determined by gas chromatography. The 4 compounds in air were adsorbed with activated carbon tube, and desorbed with CS2. Agilent 19091N-216 HP-INNOWAX Polyethylene Glycol column was used for separation, and FID was used for determination. Values of detection limit (3S/N) of hexane, acetone, 2-butanone and butyl acetate were found 0.43, 0.30, 0.44, 1.7 mg·L-1 respectively. Values of resolution factors and RSD's (n=6) found were in the ranges of 86.7%-100.3% and 1.97%-3.89% respectively.
中图分类号 O657.7
所属栏目 工作简报
基金项目
收稿日期 2011/5/7
修改稿日期
网络出版日期
作者单位点击查看
备注朱建丰(1977-),男,江苏江阴人,主管技师,从事理化检验工作。
引用该论文: ZHU Jian-feng,FENG Rong-fang,CHEN Jun. GC Determination of Hexane, Acetone, Butanone and Butyl Acetate in Air of Workplace[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2012, 48(6): 693~695
朱建丰,封蓉芳,陈军. 气相色谱法测定工作场所空气中正己烷、丙酮、丁酮和乙酸丁酯的含量[J]. 理化检验-化学分册, 2012, 48(6): 693~695
被引情况:
【1】王鹏,胡勇,祝贝思,嵇康,陈美红,徐秋凉, "溶剂解吸-气相色谱法测定空气中的氯丙烯",理化检验-化学分册 51, 710-712(2015)
【2】叶元坚,何国山,邓胡军,蔡锦安,曹志祥,潘永红, "气相色谱-质谱法测定鞋用胶粘剂中烷烃类化合物",理化检验-化学分册 50, 374-377(2014)
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】GBZ/T 160.55-2007工作场所空气有毒物质测定脂肪族酮类化合物[S].
【2】GBZ/T 160.63-2007工作场所空气有毒物质测定饱和脂肪族酯类化合物[S].
【3】GBZ/T 210.4-2008职业卫生标准制定指南第4部分:工作场所空气中化学物质测定方法[S].
【2】GBZ/T 160.63-2007工作场所空气有毒物质测定饱和脂肪族酯类化合物[S].
【3】GBZ/T 210.4-2008职业卫生标准制定指南第4部分:工作场所空气中化学物质测定方法[S].