Potentiometric Determination of Lidocaine with Solid Paraffin Lidocaine Modified Carbon Paste Electrode
摘 要
制备了一种以利多卡因与HgI42-形成的缔合物为电活性物质的固体石蜡利多卡因碳糊电极,并对其性能做了测定。结果显示:电极对利多卡因有较好的能斯特响应。利多卡因的线性范围为5.0×10-5~1.6×10-2mol·L-1,极差电位为29 mV/pc,测定下限为1.3×10-5mol·L-1。电极用于盐酸利多卡因注射液中利多卡因含量的测定,结果与药典法测定值相符。
Abstract
Solid paraffin lidocaine modified carbon paste electrode based on the complex of HgI42- with lidocaine as electroactive material was prepared and its electrochemical properties were studied. Good response of this ion selective electrode against lidocaine was obtained giving linearity range from 5.0×10-5 to 1.6×10-2mol·L-1, with a slope of 29 mV/pc and lower limit of determination of 1.3×10-5mol·L-1. The modified electrode was used in the potentiometric determination of lidocaine in lidocaine injection, and results obtained were found to be checked quite well with those found by the pharmacopoeia method.
中图分类号 O657.1
所属栏目 工作简报
基金项目 辽宁省自然科学基金项目(20102137)
收稿日期 2011/6/13
修改稿日期
网络出版日期
作者单位点击查看
备注李东辉(1963-),男,天津人,教授,博士,主要研究方向为电分析化学。
引用该论文: LI Dong-hui,LI Xiao. Potentiometric Determination of Lidocaine with Solid Paraffin Lidocaine Modified Carbon Paste Electrode[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2012, 48(8): 912~914
李东辉,李潇. 固体石蜡利多卡因碳糊电极电位法测定利多卡因[J]. 理化检验-化学分册, 2012, 48(8): 912~914
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】中国药典委员会.中华人民共和国药典(二部)[M].北京:中国医药科技出版社, 2010:709-710.
【2】秦宗会,沈光明,谭蓉,等.分光光度法测定不同介质中盐酸利多卡因的含量[J].中国药房, 2007,18(34):2692-2694.
【3】秦宗会,谭蓉,胡武洪.光度法测定盐酸利多卡因及其分析应用[J].河南师范大学学报:自然科学版, 2008,36(1):85-88.
【4】高红旺,冯波,张慧峰.紫外分光光度法测定盐酸利多卡因栓的含量[J].吉林医药学院学报, 2006,27(1):20-21.
【5】孙汉文,问海芳,苏明.毛细管电泳-联吡啶钌电化学发光测定利多卡因[J].河北大学学报:自然科学版, 2010,36(6):652-655.
【6】王玲娜,丁建.RP-HPLC法测定盐酸利多卡因注射液(溶剂用)的含量[J].江苏药学与临床研究, 2006,14(3):181-183.
【7】李剑惠.HPLC法测定复方盐酸利多卡因洗液中3组分的含量[J].中国药房, 2007,18(22):1734-1735.
【8】吴珺,戴文斌.HPLC法测定碳酸利多卡因注射液的含量[J].西北药学杂志, 2011,26(1):11-12.
【9】ABDEL R M, BIELENSTEIN M, ASKEMARK Y, et al. High-performance liquid chromatography-tandem electrospray mass spectrometry for the determination of lidocaine and its metabolites in human plasma and urine[J]. J Chromatogr B Biomed Sci Appl, 2000,741(2):175-188.
【10】孟召辉.单扫描示波极谱法测定利多卡因的研究[J].河南师范大学学报:自然科学版, 2003,31(2):70-72.
【2】秦宗会,沈光明,谭蓉,等.分光光度法测定不同介质中盐酸利多卡因的含量[J].中国药房, 2007,18(34):2692-2694.
【3】秦宗会,谭蓉,胡武洪.光度法测定盐酸利多卡因及其分析应用[J].河南师范大学学报:自然科学版, 2008,36(1):85-88.
【4】高红旺,冯波,张慧峰.紫外分光光度法测定盐酸利多卡因栓的含量[J].吉林医药学院学报, 2006,27(1):20-21.
【5】孙汉文,问海芳,苏明.毛细管电泳-联吡啶钌电化学发光测定利多卡因[J].河北大学学报:自然科学版, 2010,36(6):652-655.
【6】王玲娜,丁建.RP-HPLC法测定盐酸利多卡因注射液(溶剂用)的含量[J].江苏药学与临床研究, 2006,14(3):181-183.
【7】李剑惠.HPLC法测定复方盐酸利多卡因洗液中3组分的含量[J].中国药房, 2007,18(22):1734-1735.
【8】吴珺,戴文斌.HPLC法测定碳酸利多卡因注射液的含量[J].西北药学杂志, 2011,26(1):11-12.
【9】ABDEL R M, BIELENSTEIN M, ASKEMARK Y, et al. High-performance liquid chromatography-tandem electrospray mass spectrometry for the determination of lidocaine and its metabolites in human plasma and urine[J]. J Chromatogr B Biomed Sci Appl, 2000,741(2):175-188.
【10】孟召辉.单扫描示波极谱法测定利多卡因的研究[J].河南师范大学学报:自然科学版, 2003,31(2):70-72.
相关信息