IC Determination of Fluoride and Chloride in Sulfide Concentrate with Steam Distillation
摘 要
采用水蒸气蒸馏法分离硫化精矿样品中氟离子和氯离子,离子色谱法测定了氟离子和氯离子的含量。经AG19保护柱及AS19分离柱分离,以25.00 mmol·L-1氢氧化钠溶液为淋洗液,采用连续自动再生化学抑制器检测。F-和Cl-的质量浓度均在10.00 mg·L-1以内与峰面积呈线性关系,检出限(3s)分别为0.006,0.003 mg·L-1。方法用于分析硫化铜精矿、锌精矿和铅精矿,氟离子和氯离子的加标回收率在94.1%~97.2%,96.4%~101%之间,相对标准偏差(n=11)分别在1.5%~2.3%,1.1%~1.9%之间。
Abstract
Fluoride and Cl- ion in sulfide concentrate were separated by steam distillation, and their contents in the distillate were determined by ion chromatography. AG19 protective column and AS19 separation column were used for separation and 25.00 mmol·L-1 NaOH solution was used as eluant. Successive-auto regenerative chemical suppressor was adopted in the determination. Linear relationships between values of peak area and mass concentration of F- and Cl- were kept in the same range within 10.00 mg·L-1, with detection limits (3s) of 0.006 mg·L-1 for F- and 0.003 mg·L-1 for Cl-. The proposed method was used for the analysis of samples of copper sulfide concentrate, zinc concentrate and lead concentrate, giving values of recovery and RSD′s (n=11) in ranges of 94.1%-97.2% and 1.5%-2.3% for F-, 96.4%-101% and 1.1%-1.9% for Cl- respectively.
中图分类号 O657.7
所属栏目 工作简报
基金项目
收稿日期 2011/12/27
修改稿日期
网络出版日期
作者单位点击查看
备注刘敏(1985-),山东聊城人,助理工程师,主要从事矿产品及金属材料检测工作。
引用该论文: LIU Min,HU De-xin,WANG Zhen-kun,WANG Hao-yun,WANG Hong,LI Quan-bin,WEI Hong-bing. IC Determination of Fluoride and Chloride in Sulfide Concentrate with Steam Distillation[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2012, 48(11): 1321~1323
刘敏,胡德新,王振坤,王昊云,王虹,李权斌,魏红兵. 水蒸气蒸馏-离子色谱法测定硫化精矿中氟和氯[J]. 理化检验-化学分册, 2012, 48(11): 1321~1323
被引情况:
【1】赵 悦,胡秀芳,张 娟,刘 勇,李英秋, "高温水解-离子色谱法测定氮化硅中的氟和氯",理化检验-化学分册 52, 444-447(2016)
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】杨艳,张穗忠.电位滴定法测定萤石中的氟含量[J].冶金标准化与质量, 2007,45(5):11-13.
【2】宋晓红,高姗,杨杰,等.自动电位滴定法测定脱硫系统中氯化物[J].理化检验-化学分册, 2011,47(6):684-686.
【3】SN/T 0328-94出口氟石中氟化钙的化学分析方法[S].
【4】赵立晶,赵萍,魏月仙.流动分析-离子选择电极法测定水中痕量氟化物[J].分析化学, 2011,39(10):1526-1530.
【5】纪红玲,徐元财,王伟敏.离子选择电极法测定铁矿石中水溶性氯化物含量[J].分析试验室, 2007,26(增1):217-221.
【6】孙明山,孙忠萍,牛朝红,等.离子色谱法对生活饮用水中氟、氯、硫酸根、硝酸根阴离子的测定[J].农业与技术, 2007,27(2):89-90.
【7】MICHALSKI R. Ion chromatography as a reference method for determination of inorganic ions in water and wastewater[J]. Crit Rev Anal Chem, 2006,36(2):107-127.
【8】谢静,杨树科,戴建辉,等.离子色谱法测定瓶装水中阴离子[J].理化检验-化学分册, 2011,47(7):808-810.
【9】张明星,李华昌,于力,等.离子色谱法测定选矿废水中4种阴离子[J].理化检验-化学分册, 2011,47(1):44-46.
【10】崔海容,陈建华,谢建峰,等.水蒸气蒸馏/离子色谱法测定磷矿石中氟化物和氯化物[J].分析测试学报, 2005,24(6):92-95.
【11】王克娟,蒋仁依.水蒸气蒸馏-离子色谱法测定氟和氯[J].冶金分析, 2001,21(1):62-64.
【12】牟世芬,刘克纳,丁晓静.离子色谱方法及应用[M].北京:化学工业出版社, 2005.
【13】朱子平.离子色谱法测定防锈油中氯离子[J].冶金分析, 2009,29(10):21-23.
【14】张明星,李华昌,于力,等.离子色谱水负峰对氟离子测定的干扰消除试验研究[J].矿冶, 2010,19(2):94-96.
【2】宋晓红,高姗,杨杰,等.自动电位滴定法测定脱硫系统中氯化物[J].理化检验-化学分册, 2011,47(6):684-686.
【3】SN/T 0328-94出口氟石中氟化钙的化学分析方法[S].
【4】赵立晶,赵萍,魏月仙.流动分析-离子选择电极法测定水中痕量氟化物[J].分析化学, 2011,39(10):1526-1530.
【5】纪红玲,徐元财,王伟敏.离子选择电极法测定铁矿石中水溶性氯化物含量[J].分析试验室, 2007,26(增1):217-221.
【6】孙明山,孙忠萍,牛朝红,等.离子色谱法对生活饮用水中氟、氯、硫酸根、硝酸根阴离子的测定[J].农业与技术, 2007,27(2):89-90.
【7】MICHALSKI R. Ion chromatography as a reference method for determination of inorganic ions in water and wastewater[J]. Crit Rev Anal Chem, 2006,36(2):107-127.
【8】谢静,杨树科,戴建辉,等.离子色谱法测定瓶装水中阴离子[J].理化检验-化学分册, 2011,47(7):808-810.
【9】张明星,李华昌,于力,等.离子色谱法测定选矿废水中4种阴离子[J].理化检验-化学分册, 2011,47(1):44-46.
【10】崔海容,陈建华,谢建峰,等.水蒸气蒸馏/离子色谱法测定磷矿石中氟化物和氯化物[J].分析测试学报, 2005,24(6):92-95.
【11】王克娟,蒋仁依.水蒸气蒸馏-离子色谱法测定氟和氯[J].冶金分析, 2001,21(1):62-64.
【12】牟世芬,刘克纳,丁晓静.离子色谱方法及应用[M].北京:化学工业出版社, 2005.
【13】朱子平.离子色谱法测定防锈油中氯离子[J].冶金分析, 2009,29(10):21-23.
【14】张明星,李华昌,于力,等.离子色谱水负峰对氟离子测定的干扰消除试验研究[J].矿冶, 2010,19(2):94-96.
相关信息