摘 要
双晶纵波探头在超声波无损检测中应用广泛,因此有必要建立一个可供选择双晶探头的数学模型。根据斯涅尔定律和惠更斯原理,结合超声波声束截面上的声压差模型,建立起一个选择双晶探头的有效数学计算公式,以便用来有效地识别缺陷体的回波信号。通过对比平底孔反射回波信号的试验数据,验证了双晶探头选择的数学计算公式的正确性。
Abstract
Double-crystal P-wave probes in the ultrasonic nondestructive testing are widely used, therefore, we need to develop an alternative mathematical model of double-crystal probe.Based on Snell's law and the Huygens principle, and combined with the sound pressure difference model of beam cross section, an alternative mathematical model of double-crystal probe is established to be used effectively to identify defects in the body echo signals. By comparing of the experimental data with the flat bottom hole echo signal, the correctness of the mathematical model of choice of the double crystal probe is verified.
中图分类号 TG115.28
所属栏目 科研成果与学术交流
基金项目
收稿日期 2010/2/24
修改稿日期
网络出版日期
作者单位点击查看
备注王朝辉(1970-),男,硕士研究生,研究方向为无损检测技术的应用和发展。
引用该论文: WANG Zhao-Hui,LIU Feng,ZHOU Li. The Selection of the Double Crystal Probe in Ultrasonic Testing[J]. Nondestructive Testing, 2011, 33(1): 23~24
王朝辉,刘峰,周丽. 超声检测中双晶纵波探头的选择机理[J]. 无损检测, 2011, 33(1): 23~24
被引情况:
【1】颜晓亮,周清利, "超声检测技术在核电站蒸汽发生器中的应用",无损检测 38, 63-65(2016)
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】Charles J Hellier. Nondestructive Testing and Evaluation Handbook[M]. Beijing: China Petyochemical Press,2006:1-324.
【2】Xiao S H, Zhou Y Z, Guo J D. The effect of high current density electropulsing on persistent slip bands in fatigued copper single crystal[J]. Mater Sci & Eng A,2002,332(1):351.
【3】张海龙,孙军.工业纯铁内部疲劳微裂纹扩散愈合过程中的形态演变[J].金属学报,2002,38(3):239-244.
【2】Xiao S H, Zhou Y Z, Guo J D. The effect of high current density electropulsing on persistent slip bands in fatigued copper single crystal[J]. Mater Sci & Eng A,2002,332(1):351.
【3】张海龙,孙军.工业纯铁内部疲劳微裂纹扩散愈合过程中的形态演变[J].金属学报,2002,38(3):239-244.
相关信息