Inspection of Imported Cool Box and Defect Treatment
摘 要
在对进口冷箱的射线检测底片进行复查时,对供应商提供的4张底片评定结果提出了异议。其中3张底片的对应部位经过重新检测以及打磨后获得了一致的验收结论。但对第4张底片,在从三个方向对该缺陷进行重新拍片后,制造商判定结果为焊缝根部与垫板的收缩沟,购买方判断为未熔合缺陷。为此,分别设计了超声波检测和重新制作试件的两种方案,对各自的判定结果进行验证。验证结果证实了缺陷性质为未熔合,为进口特种设备消除了安全隐患。
Abstract
During the review for the radiographic testing film of an imported cool box, four films were found existing defects, and three of them gained the accepted result through inspection again and graining, but one film had different evaluating results between the producer and the purchaser. The producer concluded it as a defect caused by welding section, and the purchaser concluded it as a nonfusion. So two plans were designed for the conclusion of each other, and the validation results showed it as a nonfusion, and it eliminated the safety risk for the imported special equipment.
中图分类号 TG115.28
所属栏目 2011年远东无损检测论坛论文精选
基金项目
收稿日期 2011/5/31
修改稿日期
网络出版日期
作者单位点击查看
备注李绪丰(1965-),男,高级工程师,从事化机和无损检测。
引用该论文: LI Xu-Feng. Inspection of Imported Cool Box and Defect Treatment[J]. Nondestructive Testing, 2011, 33(10): 40~42