Application of Contrast Intensify Agent in Magnetic Particle Testing
摘 要
反差增强剂应用在实际磁粉检测中受到一定的约束。通过对比试验结果,分析总结了反差增强剂的施加厚度与施加速度、距离之间关系以及对检测灵敏度的影响,为实际生产中正确推广应用反差增强剂提供了经验依据。
Abstract
The application of contrast intensify agent used in magnetic particle flaw detection is always subjected to certain practical constraints. By comparing the sample test results, the relationship between the thicknesses of sprayed layers, spraying speed, and distance, as well as the detection sensitivity were detailed and summarized. The results provided an empirical basis for promoting the use of contrast intensify agent in a production environment.
中图分类号 TG115.28
所属栏目 实践经验
基金项目
收稿日期 2011/7/20
修改稿日期
网络出版日期
作者单位点击查看
备注张佩铭(1968-),男,工程师,探伤技术室主任,主要从事锅炉、压力容器等特种设备的无损检测技术工作。
引用该论文: ZHANG Pei-Ming,FAN Zhi-Yong,SONG Ying-Ying. Application of Contrast Intensify Agent in Magnetic Particle Testing[J]. Nondestructive Testing, 2012, 34(7): 40~41