Analysis of Valid Scope for MT with Prod Method and its Improvement
摘 要
目前的专业教材或者相关行业标准中对于触棒法磁粉检测的有效检测范围多为范围值或经验值.实际检测工作中,按这些标准或规范要求进行磁化的话,往往不能保证整个磁化区域各个走向的缺陷完整显示.通过现场的实际测试,针对铸件的触棒法磁化检测提出了更为准确的磁化方法:150 mm×150 mm矩形框的磁化检测,需要磁化4次才能满足要求,从而为磁粉检测人员提供有价值的参考.
Abstract
The valid inspection range for MT with probe described in professional training text booklets and in related industrial standards at present is only empirically determined.In order to improve the accuracy of detection,through the actual test in the field work,a more accurate contact prod magnetization method is proposed for magnetic particle testing of the castings.For the detection of 150mm by 150mm rectangular frame,it is needed to magnetize the frame 4 times in order to meet the requirements of the magnetization,which may provide valuable reference for magnetic particle inspection personnel.
中图分类号 TG115.28
所属栏目 实践经验
基金项目
收稿日期 2014/6/19
修改稿日期
网络出版日期
作者单位点击查看
备注高阳(1980-),男,助理工程师,主要从事无损检测技术研究工作.
引用该论文: Gao Yang,Ma Wen-jin. Analysis of Valid Scope for MT with Prod Method and its Improvement[J]. Nondestructive Testing, 2015, 37(2): 69~70
高阳,马文进. 触棒法磁粉检测有效范围的分析与改进[J]. 无损检测, 2015, 37(2): 69~70
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】全国锅炉压力容器无损检测人员资格鉴定考核委员会.磁粉探伤[M].北京:中国锅炉压力容器安全杂志社,1995.
【2】ASTM E 709—2008 磁粉检测标准程序[S].
【2】ASTM E 709—2008 磁粉检测标准程序[S].
相关信息