DEVELOPMENT AND FIELD TESTING OF TYPE SRB-HX-7 FAST TEST BOTTLE FOR SULFATE REDUCING BACTERIA
摘 要
在原SRB-HX-14型硫酸盐还原菌测试瓶的基础上,对培养基配方和生产工艺进行了优化调节,研制了SRB-HX-7型硫酸盐还原菌快速测试瓶.采用该快速测试瓶测定水样中硫酸盐还原菌的含量仅需7天就能得到结果,比原测试瓶测试时间缩短了50%.使用大庆油田四个采油厂的34份水样进行对比试验表明:SRB-HX-7型测试瓶在大大加快SRB测试速度的基础上,具有与SRB-HX-14型测试瓶相同的适应性、准确度和可靠性.
Abstract
On the basis of the original sulfate reducing bacteria SRB test bottle SRB-HX-14,the culture medium and process of production were optimized and a new type SRB-HX-7 SRB fast test bottle was developed.Adopting the new type SRB-HX-7 (SRB) fast test bottle,only 7days necessary to determine the content of SRB in water samples,so testing time was only half as the original.Contrast tests by 34 water samples from four oil production factories in Daqing Oil Field,showed that the SRB-HX-7 SRB fast test bottle accelerated the test speed,at the same time it had the same adaptability,accuracy and reliability to those of the SRB-HX-14 SRB test bottle.
中图分类号 TG174.3+7
所属栏目 应用技术
基金项目
收稿日期 2006/1/23
修改稿日期 2006/3/28
网络出版日期
作者单位点击查看
引用该论文: ZHAO Meng-yun,QU Jian-hua,ZHANG Hai-kuan,ZHAO Qing,MENG Fan-yu. DEVELOPMENT AND FIELD TESTING OF TYPE SRB-HX-7 FAST TEST BOTTLE FOR SULFATE REDUCING BACTERIA[J]. Corrosion & Protection, 2006, 27(10): 526~528
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】王升坤.硫酸盐还原菌检测技术综述[J].石油与天然气化工,1998,27(3):192-193.
【2】赵宇华,叶央芳,刘学东.硫酸盐还原菌及其影响因子[J].环境污染与防治,1997,19(5):41-43.
【3】刘宏芳,等.气相色谱/质谱在不同种类硫酸盐还原菌的鉴定中应用探讨[J].分析化学研究简报,2000,28(2):190-193.
【4】易绍金.一种快速检测SRB的新方法——免疫学法[J].石油工业技术监督,1993,(7):31-32.
【2】赵宇华,叶央芳,刘学东.硫酸盐还原菌及其影响因子[J].环境污染与防治,1997,19(5):41-43.
【3】刘宏芳,等.气相色谱/质谱在不同种类硫酸盐还原菌的鉴定中应用探讨[J].分析化学研究简报,2000,28(2):190-193.
【4】易绍金.一种快速检测SRB的新方法——免疫学法[J].石油工业技术监督,1993,(7):31-32.
相关信息