摘 要
对石脑油储罐导静电铜丝带的腐蚀失效原因进行了分析,通过腐蚀介质分析、X射线衍射定性分析、X荧光光谱定量分析和铜片腐蚀试验,对腐蚀原因和机理进行了验证.证明了铜丝带腐蚀是由石脑油中的H2S和活性硫引起的.并从设备安全运行的角度提出了改进措施.
Abstract
The reasons of corrosion failure of electrostatic copper belt for naphtha storage tank were stuclied through the analysis of corrosive medium,X-ray diffraction qualitative analysis.X-ray fluorescence spectrum quantitative analysis and copper corrosion testing.The copper belt corrosion was caused by H2S and active sulfur in naphtha.And the improvement measures were proposed from the point of view of safe operation for equipment.