Effect of Inhibitior HEDP-ATMP-TTA on Corrosion of HSn70-1A Copper-alloy
摘 要
通过静态失重法、极化曲线法、电化学阻抗谱测定了HEDP-ATMP-TTA复配缓蚀剂在循环冷却水介质中硫酸盐还原菌(SRB)作用下对HSn70-1A铜合金的协同缓蚀作用,讨论了缓蚀剂浓度和SRB对铜合金腐蚀行为的影响.结果表明:当循环冷却水介质中加入该缓蚀剂后,可以改善SRB对HSn70-1A铜合金的侵蚀程度:随着缓蚀剂浓度的增加,合金腐蚀速率逐渐下降,缓蚀率逐渐提高.
Abstract
Synergistic effect of HEDP,ATMP and TTA on corrosion inhibition of HSn70-1A copper-alloy in the industrial recirculation cooling water inoculated with SRB was studied by means of weight loss method、electrochemical polarization and electrochemical impedance spectroscopy(EIS) techniques.It was found that there was a synergistic effect between HEDP,ATMP and TTA.The corrosion rate of HSn70-1A copper-alloy descended with enhancement of concentration of the corrosion inhibitor.
中图分类号 TG174.42
所属栏目 应用技术
基金项目
收稿日期 2008/3/19
修改稿日期 2008/6/18
网络出版日期
作者单位点击查看
引用该论文: ZHENG Qiang,YAN Li. Effect of Inhibitior HEDP-ATMP-TTA on Corrosion of HSn70-1A Copper-alloy[J]. Corrosion & Protection, 2009, 30(4): 276~278
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】涂光瑜.汽轮发电机及电气设备[M].北京:中国电力出版社,1998.
【2】张天胜.缓蚀剂[M].北京:化学工业出版社,2002.
【3】曹楚南.腐蚀电化学原理[M].北京:化学工业出版社,2004.
【4】Kendig M,Mansfeld F,Tsai S.Determination of the long term corrosion behavior of coated steel with a.c.impedance measurements[J].Corrosion Science,1983,23(4):317-329.
【2】张天胜.缓蚀剂[M].北京:化学工业出版社,2002.
【3】曹楚南.腐蚀电化学原理[M].北京:化学工业出版社,2004.
【4】Kendig M,Mansfeld F,Tsai S.Determination of the long term corrosion behavior of coated steel with a.c.impedance measurements[J].Corrosion Science,1983,23(4):317-329.