The Applications of Ultrasonic Testing for PE Pipe
摘 要
测量了PE管的纵横波声速及PE管热熔焊缝声衰减系数,确定了PE管材料的声学性能。采用小波域去噪理论去除噪声,提高了检测回波的信噪比。试验表明,超声检测方法适用于PE管热熔焊缝的焊接质量检测。
Abstract
By measuring the longitudinal and shear wave velocity of PE pipe and its ultrasonic attenuation of hot-melt weld, the acoustic properties of PE pipe was determined. Wavelet denoising technique was used to remove noise, and it improved the monitoring of the echo signal-to-noise ratio. Experiments showed that ultrasonic testing method was suitable for the weld quality testing of PE pipe.
中图分类号 TG115.28 TQ317.3
所属栏目 试验研究
基金项目
收稿日期 2007/4/25
修改稿日期
网络出版日期
作者单位点击查看
备注于润桥(1963-),男,教授,研究方向为电磁超声检测技术、信号处理和系统工程应用。
引用该论文: YU Run-Qiao,XU Chang-Ying,LUO Shui-Yun,WANG Long-Wen. The Applications of Ultrasonic Testing for PE Pipe[J]. Nondestructive Testing, 2008, 30(2): 112~114
于润桥,徐长英,罗水云,王龙文. PE管超声检测试验[J]. 无损检测, 2008, 30(2): 112~114
被引情况:
【1】丁建明,孙林,张金平, "聚乙烯管材热熔对接焊接接头无损检测技术进展",无损检测 36, 91-93(2014)
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】刘舜安.PE管管材性能探讨[J].国外建材科技,2006,27(2):20-21.
【2】梁前明.PE管材的新发展及其工程应用前景[J].国外建材科技,2003,24(5):14.
【3】钱 然,钱明权.PE管材在给水系统实际应用的情况分析[J].安徽电子信息职业技术学院学报,2004,3(4):69.
【4】梅 胜.PE管应用技术发展的现状及前景分析[J].广州大学学报,2004,3(3):276-280.
【5】Munns I J, Georgiou G A, Abington U K. Ultrasonic and radiographic NDT of butt fusion welds in polyethylene pipe[D]. Watt University, Edinburgh, Scotland, UK: Plastic Pipes IX Heriot,1995:18-21.
【2】梁前明.PE管材的新发展及其工程应用前景[J].国外建材科技,2003,24(5):14.
【3】钱 然,钱明权.PE管材在给水系统实际应用的情况分析[J].安徽电子信息职业技术学院学报,2004,3(4):69.
【4】梅 胜.PE管应用技术发展的现状及前景分析[J].广州大学学报,2004,3(3):276-280.
【5】Munns I J, Georgiou G A, Abington U K. Ultrasonic and radiographic NDT of butt fusion welds in polyethylene pipe[D]. Watt University, Edinburgh, Scotland, UK: Plastic Pipes IX Heriot,1995:18-21.
相关信息