Uncertainty Evaluation for Measurement Results of Proof Strength at Non-proportional Extension of Metallic Materials
摘 要
讨论了目前对金属材料规定非比例延伸强度Rp0.2的不确定度评定的局限性,通过分析GB/T 228-2002中非比例延伸力值的确定过程,将引伸计标距引入的不确定度、引伸计测量引入的不确定度和基准线确定引入的不确定度三个不确定度分量统一到一个模型中,并合成为由引伸计引入的标准不确定度,从而解决了目前对引伸计引入的三个不确定度分量没有数学模型的问题,确定了新的Rp0.2不确定度评定方法,并运用到实例中进行了计算。
Abstract
The current limitations of uncertainty evaluation for the proof strength at non-proportional extension Rp0.2 of metallic materials were discussed. By analyzing the process of determining the non-proportional elongation force value in the standard GB /T 228-2002, three uncertainty components which were introduced by extensometer gauge length and extensometer measurement and base line determination were unified into a single model, combined into the standard uncertainty introduced by extensometer. The problem of that there was no mathematical model in three uncertainty components evaluation introduced by extensometer was solved. The new uncertainty evaluation method for Rp0.2 was established. And the uncertainty of an example was calculated by the method.
中图分类号 TG113.25
所属栏目 试验技术与方法
基金项目
收稿日期 2009/11/13
修改稿日期
网络出版日期
作者单位点击查看
备注王 俊(1976-),男,工程师,硕士。
引用该论文: WANG Jun,WANG Yu-ling. Uncertainty Evaluation for Measurement Results of Proof Strength at Non-proportional Extension of Metallic Materials[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2010, 46(9): 571~574
王俊,王玉玲. 金属材料规定非比例延伸强度测量结果不确定度评定[J]. 理化检验-物理分册, 2010, 46(9): 571~574
被引情况:
【1】王俊, "金属材料室温拉伸试验的不确定度评定",理化检验-物理分册 49, 448-456(2013)
【2】王俊,王玉玲, "金属材料力学性能测试不确定度评定的探讨",理化检验-物理分册 50, 818-821(2014)
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】GB/T 228-2002金属材料室温拉伸试验方法[S].
【2】凌霄.金属材料拉伸试验的不确定度评定[J]. 理化检验-物理分册,2004,40(6):296-299.
【3】邓星临,梁新邦.金属材料拉伸试验测量结果不确定度评定[J].物理测试,2006,24(6):16-21.
【4】傅志强. 金属材料规定非比例延伸强度Rp0.2测量结果的不确定度评定[J].理化检验-物理分册,2003,39(9):465-467.
【5】贾欣. Q345A低合金高强度结构钢力学性能的不确定度评定[J].江苏冶金,2005,33(4):1-5.
【6】中国合格评定国家认可委员会.材料理化检验测量不确定度评估指南及实例(CNAS-GL10:2006)[M]. 北京:中国计量出版社,2007.
【2】凌霄.金属材料拉伸试验的不确定度评定[J]. 理化检验-物理分册,2004,40(6):296-299.
【3】邓星临,梁新邦.金属材料拉伸试验测量结果不确定度评定[J].物理测试,2006,24(6):16-21.
【4】傅志强. 金属材料规定非比例延伸强度Rp0.2测量结果的不确定度评定[J].理化检验-物理分册,2003,39(9):465-467.
【5】贾欣. Q345A低合金高强度结构钢力学性能的不确定度评定[J].江苏冶金,2005,33(4):1-5.
【6】中国合格评定国家认可委员会.材料理化检验测量不确定度评估指南及实例(CNAS-GL10:2006)[M]. 北京:中国计量出版社,2007.
相关信息