Testing for Residual Stress of Steel Bifurcated Pipe in Hydropower Station after Vibration Stress Relief by X-ray Diffraction Method
摘 要
介绍了采用振动时效技术消减水电站钢岔管焊接残余应力,以及用X射线衍射法进行焊接残余应力测试来对振动时效效果进行定量评价。并举例说明X射线衍射测试焊接残余应力的应用情况。
Abstract
Vibration stress relief (VSR) was introduced to release the welding residual stress of bifurcated pipe in hydropower station,and X-ray diffraction residual stress testing method was also introduced to evaluate the effect of VSR. An example was given about applying the X-ray diffraction method to test residual stress of the joint of bifurcated pipe.
中图分类号 TG115.22+2.2
所属栏目 试验技术与方法
基金项目
收稿日期 2007/11/20
修改稿日期
网络出版日期
作者单位点击查看
备注靳红泽(1970-),男,高级工程师。
引用该论文: JIN Hong-ze,HU Mu-sheng. Testing for Residual Stress of Steel Bifurcated Pipe in Hydropower Station after Vibration Stress Relief by X-ray Diffraction Method[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2009, 45(1): 22~25
靳红泽,胡木生. 用X射线衍射法测定振动时效后水电站钢岔管中的残余应力[J]. 理化检验-物理分册, 2009, 45(1): 22~25