A Discussion on the Layout of Radiographic Testing of Small Diameter Tube
摘 要
针对小径管透照在实际应用中发现的问题, 以及对JB/T 4730.2—2005标准的理解, 分析了小径管经常采用倾斜透照椭圆成像的原因。探讨了小径管透照布置对纵向缺陷检出的影响, 并对小径管透照时像质计放置的位置提出了建议。对于实际检验中正确执行检测标准和提高裂纹检出率有一定的借鉴意义。
Abstract
During the process of radiographic testing of small diameter tube’s welding seam, by referring with the standard JB/T 4730.2—2005, an analysis is made with regard to the reason why diagonal exposure has to be applied on small diameter tube. A discussion is also carried out on how much the layout of radiography can effect on the indication of longitudinal flaw. Advices are also given as to the position of image quality indicator. When it comes to the execution of inspection standards as well as enhancing crack resolution, all above-mentioned endeavors are to some extent relevant and meaningful.
中图分类号 TG115.28
所属栏目 标 准 化
基金项目
收稿日期 2009/6/24
修改稿日期
网络出版日期
作者单位点击查看
备注吕 松(1974-), 男, 无损检测工程师, 无损检测高级人员, 主要从事承压设备无损检测。
引用该论文: LV Song. A Discussion on the Layout of Radiographic Testing of Small Diameter Tube[J]. Nondestructive Testing, 2010, 32(7): 513~515
吕 松. 小径管X射线检测透照布置的探讨[J]. 无损检测, 2010, 32(7): 513~515
被引情况:
【1】刘小川,武玉,万永升,谢龙光, "ITER超导导体方管铠甲焊缝的射线检测",无损检测 35, 59-61(2013)
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】JB/T 4730—2005 承压设备无损检测[S].
【2】强天鹏.射线检测[M].北京: 中国劳动社会保障出版社, 2007: 84-85.
【3】强天鹏.承压设备无损检测学习指南[M].北京: 新华出版社, 2005: 36-38.
【2】强天鹏.射线检测[M].北京: 中国劳动社会保障出版社, 2007: 84-85.
【3】强天鹏.承压设备无损检测学习指南[M].北京: 新华出版社, 2005: 36-38.