ICP-MS DETERMINATION OF ELEMENTS OF MICRO AND TRACE AMOUNTS IN LEAD GRID
摘 要
用电感耦合等离子体质谱法(ICP-MS)法直接测定铅栅板中钙、锡、铝、锑、银、铋、铁、锌、镍、镉、铜、砷等12种元素含量.样品用硝酸(1+2)溶解后,用硫酸作沉淀剂,95%-98%的铅以生成PbSO4的形式沉淀,降低了测量过程中的铅离子强度,得到了较低的检出限.加入适量的盐酸,有效地防止了锡、锑等元素的水解.选择适当的同位素,克服了测定过程中的质谱干扰,以元素45Sc、115In、204Tl作内标,采用内标法有效地补偿了因基体效应、接口效应及仪器波动的影响.方法的加标回收率为93.2%-105.0%,相对标准偏差为2.0%-7.0%.
Abstract
Simultaneous determination of 12 impurity-elements in lead grid (i.e.Ca,Sn,Al,Sb,Ag,Bi,Fe,Zn,Ni,Cd,Cu,As) of micro and trace quantities were effected by using ICP-MS.The sample was dissolved in HNO3 (1+2),and about 95%-98% of its lead content were removed by precipitation as lead sulfate.About 10 mL of HCl(1+99) was added to the filtrate to prevent the hydrolysis of tin(Ⅳ) and antimony (Ⅲ).The removal of majority of the matrix lead ion resulted lowering of matrix ion strength and making it favorable in the course of MS measurements and to obtain low detection limits for the elements determined.Besides the optimization of operation parameters of the instrument,selection of proper isotopes of the elements to be determined made it possible to overcome the mass spectrometric peak interferences to a great extent.The use of 45Sc,115In,and 204Tl as internal standards,the influences due to matrix effect,interface effect and fluctuation of the instrument were compensated effcctively.Recoveries obtained by standard addition method were in the range from 93.2% to 105.0% and RSD′s calculated from the results of determination were in the range of 2.0%-7.0%.
中图分类号 O657.31
所属栏目 工作简报
基金项目
收稿日期 2004/9/26
修改稿日期
网络出版日期
作者单位点击查看
备注黄冬根(1964-),男,江西丰城人,高级工程师,博士研究生,从事无机痕量分析研究.
引用该论文: HUAHG Dong-gen,DANG Zhi,LIAO Shi-jun,TONG Ying-dong,ZHANG Xin-quan. ICP-MS DETERMINATION OF ELEMENTS OF MICRO AND TRACE AMOUNTS IN LEAD GRID[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2006, 42(1): 31~34
黄冬根,党志,廖世军,童迎东,章新泉. ICP-MS法测定铅栅板中微量及杂质成分[J]. 理化检验-化学分册, 2006, 42(1): 31~34
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】朱松然.蓄电池手册[M].天津:天津大学出版社,2002.
【2】张坚镛,隋成运.ICP-AES测定纯铅中16个杂质元素[J].广东有色金属学报,1994,4(2):145-147.
【3】黄志英.原子吸收光谱法测定铅中微量元素铜钙铝[J].理化检验-化学分册,1994,30(4):81-83.
【4】Yourd R E,Tyson J F,Koons R D.On-line Matrix Removal of Lead for the Determination of Trace Elements in Bullet Samples by Flow Injection ICP-MS [J].Spectrochimica Acta Part B-Atomic Spectroscopy,2001,56(9):1731-1735.
【5】Keto R O.Analysis and Comparison of Ballet Lead by ICP-MS[J].J Forensic Sciences,1999,44(5):1020-1026.
【2】张坚镛,隋成运.ICP-AES测定纯铅中16个杂质元素[J].广东有色金属学报,1994,4(2):145-147.
【3】黄志英.原子吸收光谱法测定铅中微量元素铜钙铝[J].理化检验-化学分册,1994,30(4):81-83.
【4】Yourd R E,Tyson J F,Koons R D.On-line Matrix Removal of Lead for the Determination of Trace Elements in Bullet Samples by Flow Injection ICP-MS [J].Spectrochimica Acta Part B-Atomic Spectroscopy,2001,56(9):1731-1735.
【5】Keto R O.Analysis and Comparison of Ballet Lead by ICP-MS[J].J Forensic Sciences,1999,44(5):1020-1026.
相关信息