Rapid Determination of COD of Waste Water Without Using Mercuric Salt Solution
摘 要
对测定废水的化学需氧量(COD)的标准方法(GB/T 11914-1989)作了两点改进:用硫酸锰代替硫酸银作催化剂和用少量银盐代表汞盐作为氯离子的掩蔽剂.这一改进使氧化时间由原来的2 h缩短为6 min,而且彻底消除了由汞离子所带来的污染问题.试验所得优化的测定条件为:加热温度为160 ℃;回流时间为6 min;酸度为15 mol·L-1;硫酸锰的加入量为7.5 g·L-1及测定下限为100 mg·L-1 COD.
Abstract
Modification of the standard method for determination of COD of waste water (GB/T 11914-1989) was made by using Mn2+ ion instead of Ag+ as catalyst and using a small amount of Ag+ ion instead of Hg2+ as masking agent for Cl- ion.By this modification,the time of oxidation was shortened from 2 h to 6 min,and thorough elimination of the use of mercuric ion as masking agent was attained.The optimum conditions of the modified method were as follows:temperature of heating:160 ℃;time of refluxing:6 min;acidity:15 mol·L-1;amount of manganese sulfate added:7.5 g·L-1 and lower limit of determination:100 mg·L-1 COD.
中图分类号 O657
所属栏目 工作简报
基金项目 江苏省高校自然科学重大基础研究项目(06KJA61019)
收稿日期 2008/2/26
修改稿日期
网络出版日期
作者单位点击查看
备注朱雯(1973-),女,常州人,博士研究生,讲师,主要研究方向为环境工程.
引用该论文: ZHU Wen,ZHANG Wei,ZHOU Quan-fa. Rapid Determination of COD of Waste Water Without Using Mercuric Salt Solution[J]. Physical Testing and Chemical Analysis part B:Chemical Analysis, 2009, 45(4): 416~418
朱雯,张薇,周全法. 不用汞盐溶液的废水化学需氧量的快速测定[J]. 理化检验-化学分册, 2009, 45(4): 416~418
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】国家环境保护局.水和废水监测分析方法[M].北京:中国环境科学出版社,1997:354-356.
【2】黄君礼.水质分析化学[M].北京:中国建筑工业出版社,1997:165-167.
【3】BIKAS V,STEVE W W,SHELLEY J C,et al.Porter.Reduction of chloride ion interference in chemical oxygen demand (COD) determinations using bismuth-based adsorbents[J].Anal Chim Acta,1997(357):167-175.
【4】American Public Health Association.Standard Methods for the Examination of Water and Wastewater[M].New York:Water Pollution Control Federation,1985:535-538.
【5】杨明平,彭荣华,肖秋国.密封法测定焦化厂废水的COD[J].化工环保,2002,22(4):232-234.
【6】肖林如.低消耗和无汞污染的COD测定法[J].环境保护,1991,10(8):21-23.
【7】韦利杭.化学需氧量快速测定的研究[J].环境污染与防治,1995,17(3):36-37.
【8】谢振伟,于红,但德忠,等.电化学法直接快速测定COD初步研究[J].环境工程,2004,22(3):60-64.
【9】李可,赵仕林,赵凡等.化学需氧量(COD)绿色测定方法研究[J].四川师范大学学报:自然科学版,2003,26(6):649-651.
【10】中国环境监测总站《环境水质监测质量保证手册》编写组.环境水质监测质量保证手册[M].北京:化学工业出版社,1994:228.
【2】黄君礼.水质分析化学[M].北京:中国建筑工业出版社,1997:165-167.
【3】BIKAS V,STEVE W W,SHELLEY J C,et al.Porter.Reduction of chloride ion interference in chemical oxygen demand (COD) determinations using bismuth-based adsorbents[J].Anal Chim Acta,1997(357):167-175.
【4】American Public Health Association.Standard Methods for the Examination of Water and Wastewater[M].New York:Water Pollution Control Federation,1985:535-538.
【5】杨明平,彭荣华,肖秋国.密封法测定焦化厂废水的COD[J].化工环保,2002,22(4):232-234.
【6】肖林如.低消耗和无汞污染的COD测定法[J].环境保护,1991,10(8):21-23.
【7】韦利杭.化学需氧量快速测定的研究[J].环境污染与防治,1995,17(3):36-37.
【8】谢振伟,于红,但德忠,等.电化学法直接快速测定COD初步研究[J].环境工程,2004,22(3):60-64.
【9】李可,赵仕林,赵凡等.化学需氧量(COD)绿色测定方法研究[J].四川师范大学学报:自然科学版,2003,26(6):649-651.
【10】中国环境监测总站《环境水质监测质量保证手册》编写组.环境水质监测质量保证手册[M].北京:化学工业出版社,1994:228.
相关信息