Survey and Mitigation of Interference on Fujian LNG Pipeline
摘 要
为了解决福建液化天然气(LNG)管道ZZ002测试桩附近杂散电流干扰问题, 联合使用长时间电位监测手段、密间隔电位测试(CIPS)检测方法、土壤电位梯度(DCVG)检测等方法确定了管道电位异常的时间、范围和沿管道的分布状况, 发现了杂散电流的源头; 切断杂散电流干扰源后, 对管道进行复测, 管道电位恢复正常; 并对干扰现象产生的原理进行了分析、计算, 和实际测量结果进行核对, 证实联合使用时间电位监测手段、CIPS检测方法、土壤电位梯度检测等方法可以有效查找杂散电流干扰源。
Abstract
In order to solve the stray current interference problem near the Fujian LNG pipeline ZZ002 test pile, the stray current source was found by combined several methods, including CIPS, DCVG and potential detection. The interference was eliminated by turning off the stray current source and then the negative shift of potential disappeared. The strength of the interference was analyzed and computed. The contrast was completed between the computed data and the field data. It is confirmed that the combination of time potential monitoring means, CIPS, DCVG and potential detection can effectively find the stray current interference sources.
中图分类号 TG172.84 DOI 10.11973/fsyfh-201512015
所属栏目 应用技术
基金项目
收稿日期 2014/12/9
修改稿日期
网络出版日期
作者单位点击查看
备注唐赵林(1983-),工程师,本科,从事阴极保护相关工作,
引用该论文: TANG Zhao-lin. Survey and Mitigation of Interference on Fujian LNG Pipeline[J]. Corrosion & Protection, 2015, 36(12): 1180
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】SY/T 0017-2006 埋地钢质管道直流排流保护技术标准[S].
【2】胡士信. 阴极保护手册[M]. 北京: 化学工业出版社,1999:106-107.
【3】陈敬和,何悟忠,李绍忠. 抚顺地区管道直流杂散电流干扰腐蚀及防护的探讨[J]. 管道技术与设备,1999(6):13-17.
【4】杨敬杰. 地铁直流干扰影响下管道阴保电位的测试和评价[J]. 腐蚀与防护,2014, 35(3): 288-291.
【5】翁永基,李英义. (埋地管道直流干扰腐蚀研究)I检测指标和评价体系[J]. 腐蚀科学与防护技术, 2010, 22(1): 1-3.
【6】GB/T 19285-2014 埋地钢制管道防腐蚀防护工程检验[S].
【2】胡士信. 阴极保护手册[M]. 北京: 化学工业出版社,1999:106-107.
【3】陈敬和,何悟忠,李绍忠. 抚顺地区管道直流杂散电流干扰腐蚀及防护的探讨[J]. 管道技术与设备,1999(6):13-17.
【4】杨敬杰. 地铁直流干扰影响下管道阴保电位的测试和评价[J]. 腐蚀与防护,2014, 35(3): 288-291.
【5】翁永基,李英义. (埋地管道直流干扰腐蚀研究)I检测指标和评价体系[J]. 腐蚀科学与防护技术, 2010, 22(1): 1-3.
【6】GB/T 19285-2014 埋地钢制管道防腐蚀防护工程检验[S].