X射线图像灰度值与透照厚度的定量关系
          
Quantitative Relationship between Gray Value of X-ray Image and Radiographic Thickness

摘    要
X射线数字成像检测技术中, 射线图像对于沿透照方向的厚度变化, 表现为灰度值的变化, 如何由灰度值的变化得到被检物体实际厚度的变化成为业内研究的重点。基于Beer定理, 结合影响X射线机射线强度的因素和射线强度与数字图像的转换关系, 推导出灰度值与透照厚度之间的定量关系; 通过搭建试验平台, 得到系列数据, 对理论计算值和试验数据测量值进行了比对验证。结果表明: 理论灰度值与实际测试相差误差不超过灰度满量程的±10%。
标    签 X射线   数字成像   缺陷   灰度值   定量分析   X-ray   Digital imaging   Detection   Gray value   Quantitative analysis  
 
Abstract
In the technology of X-ray digital imaging detection, the X-ray imaging shows changes in gray value for thickness variations along the transillumination direction. The way how to get the object's actual thickness changes by grey value change becomes the focus of the research. In this paper, based on Beer theorem and combining with the factors influencing the intensity of X-ray machine and ray intensity and digital image transformation relations, the quantitative relationship between the grey value and thickness is deduced. By setting up the experimental platform to get series of experimental data, the theoretical calculation value and experimentally measured values are compared to verify. The results show that the difference between theoretical gray value and actual grey value is not more than gray full range of ±10%.

中图分类号 TG115.28   DOI 10.11973/wsjc201602004

 
  中国光学期刊网论文下载说明


所属栏目 试验研究

基金项目 国家重大科学仪器设备开发专项资助项目(2013YQ240803)

收稿日期 2015/6/23

修改稿日期

网络出版日期

作者单位点击查看

备注郭文明(1967-),男,副教授,主要从事图像处理的教学与科研工作。

引用该论文: GUO Wen-ming,CHEN Yu-liang. Quantitative Relationship between Gray Value of X-ray Image and Radiographic Thickness[J]. Nondestructive Testing, 2016, 38(2): 14~17
郭文明,陈宇亮. X射线图像灰度值与透照厚度的定量关系[J]. 无损检测, 2016, 38(2): 14~17


论文评价
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
分享论文
分享到新浪微博 分享到腾讯微博 分享到人人网 分享到 Google Reader 分享到百度搜藏分享到Twitter

参考文献
【1】SIM L M, TAN T C, MON A A, et al. X-ray absorption-based technique to measure the thickness of multi-layered structures[J]. Ndt & E International, 2009, 42(4):291-296.
 
【2】PENG Guang-han, YANG Xue-heng, HAN Zhong, et al. Hardening correction model of energy spectrum for continuous spectrum X-ray ICT [J].Spectroscopy and Spectral Analysis,2005,25(11):1880-1883.
 
【3】XU Guang-duo, WANG Li-qiang, TONG Jian-min. Research on calibration model of X-ray thickness gauge[J].Atomic Energy Science and Technology,2014,5:925-929.
 
【4】CHEN Ping, HAN Yan, PAN Jin-xiao. Research on X-ray multispectrum imaging based on variable energy [J].Spectroscopy and Spectral Analysis,2013,32(5):1383-1387.
 
【5】PENG G H, CAI X H, YANG X H. Numerical analysis of hardening correction model of energy spectrum for X-ray TICT[J]. Nondestructive Testing, 2007.
 
【6】CULLEN D E. A simple model model of photon transport[J].Nucl InstrumMetthodsPhys Res,1995,B 101(1):499-510.
 
【7】KOLKOORI S, WROBEL N, ZSCHERPEL U, et al. A new X-ray backscatter imaging technique for non-destructive testing of aerospace materials[J]. Ndt & E International, 2014,70:41-52.
 
【8】SELTZER S M. Calculation of photon mass enery-transfer and mass enery-absorbtioncoefficient[J].Radiat Res,1993,136(2):147-170.
 
【9】REZA H P R, REZAIE A H, SADEGHI S H H, et al. A density-based fuzzy clustering technique for non-destructive detection of defects in materials[J]. Ndt& E International,2007,40(4):337-346.
 
【10】CASALTA S, DAQUINO G G, METTEN L, et al. Digital image analysis of X-ray and neutron radiography for the inspection and the monitoring of nuclear materials[J]. Ndt & E International,2003,36(5):349-355.
 
【11】赵肖东,蔡建刚,陈明,等. 航空零部件X射线数字成像检测系统[J]. 无损检测, 2013, 35(4):57-59.
 
【12】王玮,李公平,潘小东,等. 工业CT锥束X射线能谱及强度的分布模拟[J].无损检测,2014,36(3):9-13.
 
【13】冯长春,周炜. X射线衰减系数与射线管电压的关系初探[J].无损探伤,1997,19(1):11-13.
 
【14】高阔,于虹,郭铁桥. 射线数字成像(DR)技术在电力工业检测中的应用[J]. 无损检测, 2013, 35(11):76-78.
 
【15】连广, 王庭魁.材中X射线衰减规律的验证及吸收系数测定[J].林业科技, 1990(6):28-30.
 
相关信息
   标题 相关频次
 X射线数字成像技术在电力电缆现场检测中的应用
 4
 α-氧化铝的X射线定量分析
 4
 基于X射线数字照相技术的电力电缆缺陷的CR与DR检测对比
 4
 X射线数字成像在压力管道检测中的应用
 3
 高压电缆阻水缓冲层烧蚀缺陷的射线检测
 3
 管道内外壁缺陷的漏磁检测
 3
 图像增强器式线阵列X射线数字成像系统
 3
 《机械工程材料》刊载的基金资助论文及其作者的定量分析
 2
 304不锈钢在RCC-M1310标准下的耐蚀性
 2
 LNG钢瓶X射线智能检测装置的设计与应用
 2
 TOFD技术在球罐定期检验中的应用
 2
 X射线TICT中能谱硬化修正模型的数值分析
 2
 X射线光电子能谱法分析爆炸残留物
 2
 X射线数字成像技术在电力电缆现场检测中的应用
 2
 X射线数字成像技术在埋弧焊管焊缝检测中的应用
 2
 X射线数字实时成像检测技术在浅海钢管铺设中的应用
 2
 X射线衍射法定量分析蓝晶石样品
 2
 X射线衍射线的计算机模拟
 2
 X射线源透射式工业计算机断层扫描成像技术在复合材料工件检测中的散射修正
 2
 比色法测定声表面波化学传感器膜材料(SXFA)的叔羟基
 2
 变电站X射线检测的防护措施
 2
 彩色金相在显微组织分析中的应用
 2
 残余奥氏体对05Cr17Ni4Cu4Nb钢逆变奥氏体含量的影响
 2
 残余应力的超声检测方法
 2
 草甘膦分析方法的研究进展
 2
 差分卫星定位技术在管道爬行器X射线检测中的应用
 2
 掺烧劣质煤对供电煤耗影响的分析
 2
 超高效液相色谱-四极杆-飞行时间质谱法定性筛查和定量分析血液中110种农药
 2
 粗SiC颗粒对再结晶碳化硅陶瓷抗热震性能的影响
 2
 单糖和二糖的定量分析的研究进展
 2