The Analysis and Processing for Electrical Conductivity Test of 7075-T6 Aluminum Material
摘 要
铝合金热处理质量的检验一般是通过测量其电导率来进行间接评价的。使用Sigmatest 2.069涡流电导率仪,测量厚度为0.04英寸7075-T6包铝材料的电导率时,发现测量结果始终不符合验收标准。对此,进行了原因分析和验证试验,重新确定了仪器制造商提供的Sigmatest 2.069修正表中厚度为0.04英寸包铝材料的电导率修正值。
Abstract
Quality test of aluminum alloy heat treatment is often done by an indirect evaluation of measuring the conductivity. It was found that, when the Sigmatest 2.069 eddy current conductivity instrument was used to measure the electrical conductivity of 7075-T6 aluminum materials of thickness 0.04 inches, the measured results were always not in conformity with the acceptance standard. Detailed analysis and a large number of verification tests were carried out in order to find the cause, and finally the correction values in the Sigmatest 2.069 table for aluminum alloy of thickness 0.04 inches were revised.
中图分类号 TG115.28 DOI 10.11973/wsjc201604011
所属栏目 试验研究
基金项目
收稿日期 2015/8/9
修改稿日期
网络出版日期
作者单位点击查看
备注钟丽英(1969-),女,工程师,本科, 主要从事无损检测工作。
引用该论文: ZHONG Li-ying,ZHANG Ya-rong,XUE Lei,ZHANG Jing-tong,YANG Shu-qin. The Analysis and Processing for Electrical Conductivity Test of 7075-T6 Aluminum Material[J]. Nondestructive Testing, 2016, 38(4): 41~44
钟丽英,张亚荣,薛磊,张敬彤,杨书勤. 7075-T6包铝材料电导率测试分析和处理[J]. 无损检测, 2016, 38(4): 41~44
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】国防科技工业无损检测人员资格鉴定与认证培训教材编审委员会编.涡流检测[M].北京:机械工业出版社2004.
【2】任吉林,林俊明.电磁无损检测[M].北京:科学出版社2004.
【2】任吉林,林俊明.电磁无损检测[M].北京:科学出版社2004.