Verification of RT Crystal Diffraction Image of the Centrifugal Casting Tube for PWR Coolant System
摘 要
对CPR1000压水堆冷却剂系统离心铸造管进行射线检测时, 在底片上发现大面积黑白相间、边缘分界不清晰、没有规律性的不规则斑纹状或斑状的疑似缺陷影像显示。通过各种物理化学和无损检测方法对影像进行排除和验证, 并与铸件典型缺陷图谱中的缺陷影像进行比较, 判定其属于晶间衍射产生的非缺陷类影像显示, 并进行了形成机理的分析。
Abstract
On RT testing of centrifugal casting pipe of CPR1000 PWR coolant system, an image on the film with a large area of black and white, and with unclear edge boundary was found. The image was also characteristic of irregular patch or defect image. Through a variety of physical and chemical methods and non-destructive examination methods for exclusion and verification and by comparing it with the defect image of typical casting defect map, it was verified that the image was the non-defect image caused by the crystal diffraction, and following on its formation mechanism was analyzed.
中图分类号 TG115.28 DOI 10.11973/wsjc201609009
所属栏目 试验研究
基金项目
收稿日期 2016/1/8
修改稿日期
网络出版日期
作者单位点击查看
备注朱从斌(1974-),男, 高级工程师, 主要从事无损检测技术研究和机械设备质量监督工作。
引用该论文: ZHU Cong-bin,LI Mao-yu,WANG Jian-jun. Verification of RT Crystal Diffraction Image of the Centrifugal Casting Tube for PWR Coolant System[J]. Nondestructive Testing, 2016, 38(9): 33~36
朱从斌,李茂宇,王建军. 压水堆冷却剂系统离心铸造管射线检测晶间衍射影像验证[J]. 无损检测, 2016, 38(9): 33~36
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】RCC-M 2000 Edition & addendum 2002 deign and construction rules for mechanical components of PWR nuclear islands [S].
【2】ASTM E 186-93 Standardreference radiographs for heavy-walled (51 to 114 mm) steel castings[S].
【3】ASTM E 446-93 Standard reference radiographs for steel castings up to 51 mm in thickness[S].
【2】ASTM E 186-93 Standardreference radiographs for heavy-walled (51 to 114 mm) steel castings[S].
【3】ASTM E 446-93 Standard reference radiographs for steel castings up to 51 mm in thickness[S].