Analysis on Leakage Reasons of the Heat Transfer Tube of Cooling System of the Nuclear Island Facility in a Power Station
摘 要
某电站核岛设备冷却系统的传热管频发泄漏故障,发生泄漏的传热管材料为紫铜,泄漏点位于弯管和直管之间的焊缝上。采用化学成分分析、金相检验、扫描电镜及能谱分析、X射线衍射分析等方法分析了该传热管穿孔泄漏的原因。结果表明:铜管母材基本完好,整个泄漏通道沿焊缝发展,泄漏通道在管道内表面的开口宽度大于管道外表面的开口宽度,失效起源于铜管内侧焊缝上的缺陷;焊丝中的磷元素含量超标导致的焊缝组织中的缺陷,以及焊缝中存在大量气孔是引发泄漏的主要原因。
Abstract
In a power station, leakage failure occurred to a heat transfer tube of the nuclear island cooling system frequently. The leaked heat transfer tube was made up of red copper, and the leak points lay on the welding seam between the elbow tube and straight tube. The leakage reasons were studied by chemical composition analysis, metallographic examination, electron microscope and energy spectrum analysis, X-ray diffraction analysis and so on. The results show that:the basic metal of the copper tube didn't suffer damage; the leakage path developed alone the welding seam, and the width of the leakage path in the inner tube was wider than that in the outer tube; the failure was originated from the defect of the welding seam in inner tube; the excess of phosphorous resulted in the defect in the welding seam, and plenty of bubbles existed in the welding seam, which were the main reasons of the leakage.
中图分类号 TG115.2 DOI 10.11973/lhjy-wl201701012
所属栏目 质量控制与失效分析
基金项目
收稿日期 2016/3/15
修改稿日期
网络出版日期
作者单位点击查看
备注王浩(1985-),男,硕士,主要从事核结构材料研发及应用研究,wanghao1224@qq.com。
引用该论文: WANG Hao,WEI Guang-qiang,XU Qi. Analysis on Leakage Reasons of the Heat Transfer Tube of Cooling System of the Nuclear Island Facility in a Power Station[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2017, 53(1): 51~57
王浩,魏光强,徐祺. 某电站核岛设备冷却系统传热管的泄漏原因分析[J]. 理化检验-物理分册, 2017, 53(1): 51~57
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】巴发海,柴泽,陈俊伟.TU2铜管泄漏原因分析[J].理化检验-物理分册,2014,50(4):306-309.
【2】钱锟,冯凌超,韩波.R290铜管道爆裂原因分析[J].理化检验-物理分册,2016,52(4):270-273.
【3】SUBRAMANIAN P R, CHAKRABARTI D J, LAUGHLIN D E. Phase Diagrams of Binary Copper Alloys[M]. Cleveland:ASM International, 1994.
【4】张玉福.紫铜在内冷水介质中腐蚀行为的交流阻抗测试和分析[J].湖南电力技术,1991,1(5):7-13.
【5】谢学军,朱庆胜,樊华,等.水内冷发电机空芯铜导线腐蚀行为研究[J].腐蚀科学与防护技术,2005,17(6):429-431.
【6】谢学军,曹顺安,潘玲,等.水内冷发电机空芯铜导线的防腐蚀[J].材料防护,2007,40(10):75-77.
【2】钱锟,冯凌超,韩波.R290铜管道爆裂原因分析[J].理化检验-物理分册,2016,52(4):270-273.