核电厂板式热交换器的泄漏原因
          
Leakage Reasons for Plate Heat Exchanger in Nuclear Power Plant

摘    要
采用冲刷腐蚀试验研究了某核电厂SEM板式热交换器的泄漏原因。结果表明:穿孔泄漏的直接原因是海水中泥沙含量大;泥沙等在流道内沉积,造成流道变窄,使得流速增大是穿孔泄漏的根本原因。
标    签 板式热交换器   冲刷腐蚀   核电厂   措施   plate heat exchanger   erosion corrosion   nuclear power plant   measure  
 
Abstract
Erosion corrosion test was used to study the leakage reason for a plate heat exchanger in a nuclear power plant. The results revealed that the direct cause of perforation was the high sand contents in sea water. And the root cause of perforation was the deposition of sand in the flow channel, resulting in a narrow channel, which makes the flow rate increase.

中图分类号 TG172   DOI 10.11973/fsyfh-201707003

 
  中国光学期刊网论文下载说明


所属栏目 核电设备材料防护

基金项目

收稿日期 2016/4/29

修改稿日期

网络出版日期

作者单位点击查看


引用该论文: LAI Ping,MENG Mingqiang,ZHANG Lefu. Leakage Reasons for Plate Heat Exchanger in Nuclear Power Plant[J]. Corrosion & Protection, 2017, 38(7): 499


论文评价
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
分享论文
分享到新浪微博 分享到腾讯微博 分享到人人网 分享到 Google Reader 分享到百度搜藏分享到Twitter

参考文献
【1】何西扣,董毅. 核电站用板式换热器失效分析[J]. 物理测试,2010,28(2):55.
 
【2】苗学良,康晓军. 核电厂板式热交换器钛板穿孔分析[J]. 腐蚀科学与防护技术,2013,25(5):442-444.
 
【3】杨冬. 田湾核电站凝汽器真空系统板式热交换器缺陷及处理[J]. 中国核电,2015(1):34-37.
 
【4】孟铭强,张乐福,韩光辉,等. 闭式冷却水板式换热器的应用与维护[J]. 发电设备,2014(6):435-437.
 
【5】朱娟,张乔斌. 冲刷腐蚀的研究现状[J]. 中国腐蚀与防护学报,2014,34(3):199-210.
 
【6】李平. 酸性液固两相流中不锈钢冲刷腐蚀行为的研究[D]. 武汉:华中科技大学,2006.
 
【7】XU J,ZHUO C Z,HAN D Z,et al. Erosion-corrosion behavior of nanoparticle reinforced Ni matrix composite alloying layer by duplex surface treatment in aqueous slurry environment[J]. Corros Sci,2009,51(5):1055-1068.
 
【8】ZHANG G A,XU L Y,CHENG Y F. Investigation of erosion-corrosion of 3003 aluminum alloy in ethylene glycol-water solution by impingement jet system[J]. Corros Sci,2009,51(2):283-290.
 
【9】MENG H,HU X,NEVILLE A. A systematic erosion-corrosion study of two stainless steels in marine conditions via experimental design[J]. Wear,2007,263(1/6):355-362.
 
【10】HU X,NEVILLE A. An examination of the electrochemical characteristics of two stainless steels (UNS S32654 and UNS S31603) under liquid-solid impingement[J]. Wear,2004,256(5):537-544.
 
【11】ZHENG Y G,YU H,JIANG S L,et al. Effect of the sea mud on erosion corrosion behaviors of carbon steel and low alloy steel in 2.4% NaCl solution[J]. Wear,2008,264(11/12):1051-1058.
 
【12】刘新宽,方其先. 两种不锈钢冲刷腐蚀的研究[J]. 化工机械,1998,25(1):12-15.
 
【13】吴成红,甘复兴. 金属在两相流动水体中的冲刷腐蚀[J]. 材料保护,2000,33(4):33-35.
 
【14】徐哲. 液固两相流条件下P110钢冲刷腐蚀研究[D]. 大庆:东北石油大学,2011.
 
相关信息
   标题 相关频次
 316L奥氏体不锈钢在高温水中的应力腐蚀
 4
 Zr-2.5Nb压力管材的氧化腐蚀行为影响因素
 4
 Zr-Nb系合金在360 ℃/20 MPa溶氧水中的腐蚀行为
 4
 反应堆事故下安全壳地坑水池的化学效应
 3
 核电厂二回路管道腐蚀降级特征分析与敏感点识别
 3
 核电厂海水循环泵用两种耐腐蚀涂层
 3
 利用直流电压法在线测试碳钢的流动加速腐蚀减薄速率
 3
 在线测试碳钢流动加速腐蚀减薄速率的直流电压法
 3
 304L不锈钢在高温高压水中的腐蚀疲劳裂纹扩展行为
 2
 35CrMo钢在含砂胍胶溶液中的冲刷腐蚀行为和机理
 2
 5 Mt/a常减压装置常顶空冷出口集合管腐蚀泄漏原因及防腐蚀建议
 2
 AP1000核电厂安全壳厂房混凝土涂层失效分析
 2
 Ni-P-Al2O3镀层的腐蚀、冲刷腐蚀和磨损行为
 2
 P110油管腐蚀穿孔原因分析
 2
 奥氏体不锈钢在海水环境中的腐蚀疲劳裂纹扩展行为
 2
 表面粗糙度对800H合金在超临界水环境中腐蚀行为的影响
 2
 常减压装置减压炉出口热电偶套管失效分析
 2
 超临界二氧化碳环境中800H合金的均匀腐蚀行为
 2
 船舶冷却系统铜镍合金管腐蚀穿孔原因
 2
 大庆与俄罗斯原油混炼中的安全防腐蚀技术
 2
 反应堆压力容器用508Ⅲ低合金钢在高温高压硼锂水环境中的应力腐蚀开裂行为
 2
 高压加热器性能劣化和换热器监管优化
 2
 工业建筑防腐蚀工程施工技术措施
 2
 管道3PE防护层的结构特点与缺陷分析及防范
 2
 核电厂BOSS头焊缝的无损检测要求
 2
 核电厂超声检测技术的应用
 2
 核电厂衬胶设备的老化管理
 2
 核电厂二回路汽水管道局部减薄管理的挑战和应对
 2
 核电厂鼓型滤网牺牲阳极溶解不足的原因
 2
 核电厂管道射线插塞焊缝的无损检测
 2