Reason Analysis on Bursting of the Inlet Heating Surface Pipe of a Boiler's Cyclone Separator
摘 要
通过宏观分析、化学成分分析、力学性能试验、金相检验、断口扫描电镜分析等方法对某锅炉旋风分离器进口受热面管爆裂原因进行了分析。结果表明:该锅炉受热面管爆裂是由长时间超温运行导致的蠕变开裂造成的。最后根据爆管原因提出了预防措施。
Abstract
The bursting reasons of the inlet heating surface pipe of a boiler's cyclone separator were analyzed by means of macro analysis, chemical composition analysis, mechanical property test, metallographic examination, fracture scanning electronic microscope analysis and so on. The results show that the bursting of the heating surface pipe of the boiler was induced by creep cracking because of long-time overtemperature running. Finally, preventive measures were put forward according to the bursting reasons of the pipe.
中图分类号 TM621.2 DOI 10.11973/lhjy-wl201710016
所属栏目 质量控制与失效分析
基金项目
收稿日期 2016/9/5
修改稿日期
网络出版日期
作者单位点击查看
备注戈浩(1988-),男,工程师,硕士,主要从事电厂金属监督及无损检测工作,gehao314@126.com
引用该论文: GE Hao,JIN Nanhui,LIU Jie,ZHAO Li. Reason Analysis on Bursting of the Inlet Heating Surface Pipe of a Boiler's Cyclone Separator[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2017, 53(10): 765~767
戈浩,金南辉,刘杰,赵立. 锅炉旋风分离器进口受热面管爆裂原因分析[J]. 理化检验-物理分册, 2017, 53(10): 765~767
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】王俊霖,刘敏,张萍,等.T91高温过热器管爆裂原因分析[J].理化检验-物理分册,2013,49(9):618-621,624.
【2】赵永宁,刘爽.102钢高温过热器管内壁氧化皮脱落研究[J].热加工工艺,2010,39(22):203-206.
【3】蒙新明,张路,赖云亭,等.某超临界机组锅炉过热器管爆管原因分析[J].理化检验-物理分册,2015,51(5):353-357.
【4】敖哲.锅炉水冷壁爆管原因分析[J].理化检验-物理分册,2014,50(4):296-298.
【5】蔡文河,严苏星.电站重要金属部件的失效及其监督[M].北京:中国电力出版社,2009.
【6】包文东,郑坊平,崔雄华,等.超临界锅炉末级过热器T91钢管爆管原因分析及预防措施[J].理化检验-物理分册,2012,48(10):704-707.
【2】赵永宁,刘爽.102钢高温过热器管内壁氧化皮脱落研究[J].热加工工艺,2010,39(22):203-206.
【3】蒙新明,张路,赖云亭,等.某超临界机组锅炉过热器管爆管原因分析[J].理化检验-物理分册,2015,51(5):353-357.
【4】敖哲.锅炉水冷壁爆管原因分析[J].理化检验-物理分册,2014,50(4):296-298.
【5】蔡文河,严苏星.电站重要金属部件的失效及其监督[M].北京:中国电力出版社,2009.
【6】包文东,郑坊平,崔雄华,等.超临界锅炉末级过热器T91钢管爆管原因分析及预防措施[J].理化检验-物理分册,2012,48(10):704-707.
相关信息