Sensitivity Influencing Factors of Radiographic Inspection of Large Diameter Thick-Walled Butt Girth Welding Seam in Nuclear Power Plant
摘 要
针对核电站大直径厚壁环焊缝射线检测灵敏度下降的问题,以核电站主管道为试验对象,对缺陷自身高度、缺陷宽度、射线源焦点尺寸、缺陷深度、射线源角度和射线源位置等主要影响因素进行重点分析,通过CIVA软件的模拟,以及带缺陷试块的透照试验,得出了影响射线检测灵敏度的几个重要因素。
Abstract
Due to the sensitivity of the X-ray inspection decreased in thick-walled workpiece inspection, the main pipeline of nuclear power plant was used as the research object, and the major influencing factors of the height and width of the defect, the X-ray focus size, defect depth, and the angle and position of X-ray source were analyzed. Through the software CIVA simulation and radiography of test block, several important factors affecting the sensitivity of radiographic inspection were shown.
中图分类号 TG115.28 DOI 10.11973/wsjc201805009
所属栏目 民用核电无损检测技术发展与应用专题
基金项目
收稿日期 2017/11/7
修改稿日期
网络出版日期
作者单位点击查看
备注梅义俊(1983-),男,学士,工程师,主要从事核电站在役检查工作
引用该论文: MEI Yijun,WANG Qi,WEN Qingquan,YIN Bangyao,SU Haimin,HUA Xiongfei. Sensitivity Influencing Factors of Radiographic Inspection of Large Diameter Thick-Walled Butt Girth Welding Seam in Nuclear Power Plant[J]. Nondestructive Testing, 2018, 40(5): 36~41
梅义俊,王琪,温庆全,银帮耀,苏海敏,华雄飞. 核电站大直径厚壁对接环焊缝射线检测灵敏度的影响因素[J]. 无损检测, 2018, 40(5): 36~41
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】闫业良, 李晓泉, 邹华. 大厚壁压力容器封头焊接工艺研究[J]. 焊接技术,2014(12):35-37.
【2】强天鹏, 宋继红, 王晓雷, 等. 射线检测[M]. 北京:中国劳动社会保障出版社, 2007.
【3】严宇, 魏鹏, 刘丽丽,等. CIVA软件仿真曝光次数对射线检测结果的影响[J]. 无损探伤,2014,38(2):19-21.
【4】牛继承, 张玉祥, 王任甫. 大壁厚14CrNi5MoV铸钢的组织及力学性能研究[J]. 铸造技术, 2011, 32(8):1078-1080.
【2】强天鹏, 宋继红, 王晓雷, 等. 射线检测[M]. 北京:中国劳动社会保障出版社, 2007.
【3】严宇, 魏鹏, 刘丽丽,等. CIVA软件仿真曝光次数对射线检测结果的影响[J]. 无损探伤,2014,38(2):19-21.
【4】牛继承, 张玉祥, 王任甫. 大壁厚14CrNi5MoV铸钢的组织及力学性能研究[J]. 铸造技术, 2011, 32(8):1078-1080.