Cause Analysis of Perforation on the Blind Head of Bottom Exit Pipeline of FPSO Flash Tank A for Production Water
摘 要
某FPSO生产水闪蒸罐A底部出口管线的盲封头在运行过程中发生了穿孔失效。采用宏观检验、化学成分分析、金相检验、细菌检测、扫描电镜及能谱分析等方法对该盲封头穿孔的原因进行了分析。结果表明:该盲封头底部有较多油砂淤积,内壁不均匀附着了多处结块,造成了局部沉积物下腐蚀,沉积物的淤积促进了硫酸盐还原细菌(SRB)繁殖,细菌腐蚀产物的侵蚀作用导致盲封头最终发生穿孔失效。
Abstract
Perforation failure on blind head of bottom exit pipeline of a FPSO flash tank A for production water occurred during service. Perforation causes of blind head were analyzed by macroscopic inspection, chemical composition analysis, metallographic examination, bacterial detection, scanning electron microscope and energy spectrum analysis. The results show that oil sands were deposited at bottom of the blind head. Inhomogeneous attachments on the inner wall of blind head resulted in local corrosion under depositions. Sediment deposition promoted SRB reproduction, and the erosion effect of bacterial corrosion products led to perforation failure of the blind head.
中图分类号 TG174 DOI 10.11973/lhjy-wl201912012
所属栏目 质量控制与失效分析
基金项目
收稿日期 2019/9/10
修改稿日期
网络出版日期
作者单位点击查看
备注杨阳(1987-),男,工程师,硕士,主要从事金属材料失效分析工作,yangyang38@cnooc.com.cn
引用该论文: YANG Yang,LUO Yi,WANG Haifeng,LIU Liang,YANG Zhongna,JIANG Lei. Cause Analysis of Perforation on the Blind Head of Bottom Exit Pipeline of FPSO Flash Tank A for Production Water[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2019, 55(12): 873~877
杨阳,罗懿,王海锋,刘亮,杨中娜,姜磊. FPSO生产水闪蒸罐A底部出口管线盲封头穿孔原因分析[J]. 理化检验-物理分册, 2019, 55(12): 873~877
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】叶帆,高秋英. 凝析气田单井集输管道内腐蚀特征及防腐技术[J]. 天然气工业,2010,30(4):96-101.
【2】严焱诚,陈大钧,薛丽娜. 油气井中的湿硫化氢腐蚀与防护[J]. 全面腐蚀控制,2004,18(4):7-9.
【3】胡建国,罗慧娟,张志浩. 长庆油田某输油管道腐蚀失效分析[J]. 腐蚀与防护,2018,39(12):962-965.
【4】张国礼,秦立峰,张峙,等. 某海底管道失效分析[J]. 西安石油大学学报(自然科学版),2013,28(1):98-101.
【5】黄辉,马红莲,何仁洋,等. 某天然气站场管道典型管件内腐蚀原因分析[J]. 理化检验(物理分册),2015,51(9):653-656.
【6】赵锋洛,杨辉,黄雪松,等. 油田注入水环境下套管腐蚀失效分析[J]. 焊管,2003,26(2):16-18.
【7】叶正荣,桂晶,裘智超,等. 某油田地面注水管线腐蚀失效分析[J]. 材料保护,2018,51(11):148-151.
【2】严焱诚,陈大钧,薛丽娜. 油气井中的湿硫化氢腐蚀与防护[J]. 全面腐蚀控制,2004,18(4):7-9.
【3】胡建国,罗慧娟,张志浩. 长庆油田某输油管道腐蚀失效分析[J]. 腐蚀与防护,2018,39(12):962-965.
【4】张国礼,秦立峰,张峙,等. 某海底管道失效分析[J]. 西安石油大学学报(自然科学版),2013,28(1):98-101.
【5】黄辉,马红莲,何仁洋,等. 某天然气站场管道典型管件内腐蚀原因分析[J]. 理化检验(物理分册),2015,51(9):653-656.
【6】赵锋洛,杨辉,黄雪松,等. 油田注入水环境下套管腐蚀失效分析[J]. 焊管,2003,26(2):16-18.
【7】叶正荣,桂晶,裘智超,等. 某油田地面注水管线腐蚀失效分析[J]. 材料保护,2018,51(11):148-151.
相关信息