Leakage Causes of Plate Heat Exchanger
摘 要
某不锈钢板式换热器出现早期泄漏。采用化学成分分析、宏微观观察、能谱分析、金相检验、非金属夹杂物分析、硬度测试及水质分析等方法,对板式换热器的泄漏原因进行了分析。结果表明:循环水水质异常,里面含有的高氯化物使板式换热器不锈钢板产生点蚀,随着点蚀程度增加,最终导致板式换热器穿孔泄漏。
Abstract
Early leakage occurred in a stainless steel plate heat exchanger. The leakage causes of the plate heat exchanger were analyzed by means of chemical composition analysis, macro and micro observation, energy spectrum analysis, metallographic examination, non-metallic inclusion analysis, hardness test and water quality analysis. The results show that the water quality of circulating water was abnormal, and the high chloride in it caused pitting corrosion of the stainless steel plate of the plate heat exchanger. With the increase of pitting corrosion degree, the perforation leakage of plate heat exchanger was caused.
中图分类号 TG115.2 DOI 10.11973/lhjy-wl202106017
所属栏目 质量控制与失效分析
基金项目
收稿日期 2020/7/22
修改稿日期
网络出版日期
作者单位点击查看
备注申志清(1984-),男,工程师,主要从事金属材料理化检验及失效分析工作,zqshen214@163.com
引用该论文: SHEN Zhiqing,JIANG Chengli,WANG Fei. Leakage Causes of Plate Heat Exchanger[J]. Physical Testing and Chemical Analysis part A:Physical Testing, 2021, 57(6): 75~77
申志清,姜成利,王飞. 板式换热器泄漏原因[J]. 理化检验-物理分册, 2021, 57(6): 75~77
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】徐云武, 黄长山,吴晋英,等.板式换热器的清洗[J].清洗世界,2010,26(1):39-43.
【2】王荣.机械装备的失效分析(待续)第1讲现场勘探技术[J].理化检验(物理分册),2016,52(6):361-369.
【3】王荣.机械装备的失效分析(续前)第3讲断口分析技术(上)[J].理化检验(物理分册),2016,52(10):698-704.
【4】全国锅炉压力容器标准化技术委员会.板式热交换器第1部分:可拆卸板式热交换器:NB/T 47004.1-2017[S].北京:新华出版社,2017.
【5】刘发安.不锈钢钢管腐蚀原因分析[J].化工设备与管道,2017,54(6):68-72.
【2】王荣.机械装备的失效分析(待续)第1讲现场勘探技术[J].理化检验(物理分册),2016,52(6):361-369.
【3】王荣.机械装备的失效分析(续前)第3讲断口分析技术(上)[J].理化检验(物理分册),2016,52(10):698-704.
【4】全国锅炉压力容器标准化技术委员会.板式热交换器第1部分:可拆卸板式热交换器:NB/T 47004.1-2017[S].北京:新华出版社,2017.
【5】刘发安.不锈钢钢管腐蚀原因分析[J].化工设备与管道,2017,54(6):68-72.