Comparison of General Corrosion Behavior between Domestic and Imported Alloy 690TT Heat-Exchanger Tubes
摘 要
分析对比了国产和进口690TT合金传热管材料的显微组织,确认两者的显微组织差异不明显后,在模拟核电厂高温高压一回路水环境(300℃、10 MPa、1 200 mg/L B、2.2 mg/L Li)中分别测量了这两种管材试样在5 μg/L和100 μg/L溶解氧(DO)条件下的开路电位和弱极化曲线,通过测试腐蚀过程中的电化学动力参数自腐蚀电流密度(Jcorr)计算了平均腐蚀速率(vcorr)。结果表明:DO<5 μg/L时,国产和进口管材的平均腐蚀速率分别为0.68 μm/a和0.71 μm/a;DO为100 μg/L时,平均腐蚀速率分别为0.81 μm/a和0.85 μm/a。溶解氧会促进合金的腐蚀,但国产和进口管材在试验条件下的平均腐蚀速率均很低,均匀腐蚀性能差别不大。
Abstract
Metallographic and microstructure of domestic and imported 690TT alloy heat transfer tube materials were analyzed and compared. After confirming that the microstructure difference between the two was not obvious, the open circuit potential and weak polarization curves of the two tube samples under 5 μg/L and 100 μg/L dissolved oxygen (DO) conditions were measured in a simulated nuclear power plant's high temperature and high pressure primary circuit water environment(300℃, 10 MPa, 1 200 mg/L B, 2.2 mg/L Li). The average corrosion rate (vcorr) was calculated by testing the electrochemical dynamic parameter Jcorr in the corrosion process. The results showed that when DO<5 μg/L, the average corrosion rates of domestic and imported tube were 0.68 μm/a and 0.71 μm/a, respectively; when DO was 100 μg/L, the average corrosion rates were 0.81 μm/a and 0.85 μm/a, respectively. Dissolved oxygen would promote the corrosion of the alloy, but the average corrosion rates of domestic and imported tube under the test conditions were very low, and the general corrosion characters were almost the same.
中图分类号 TG172 DOI 10.11973/fsyfh-202112002
所属栏目 试验研究
基金项目 国家重点研发计划(2019YFB1900904);国家科技重大专项(2018ZX06002008)
收稿日期 2021/8/15
修改稿日期
网络出版日期
作者单位点击查看
引用该论文: ZHENG Hui,LI Jie,YANG Shuangliang,ZHONG Zhimin,SUN Wei,LIU Ji,ZHANG Zhiming. Comparison of General Corrosion Behavior between Domestic and Imported Alloy 690TT Heat-Exchanger Tubes[J]. Corrosion & Protection, 2021, 42(12): 8
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】刘晓强,刘冀,孙伟,等. 不同水化学条件下800合金传热管的均匀腐蚀性能[J]. 腐蚀与防护,2020,41(9):20-26.
【2】BARNARTT S. Two-point and three-point methods for the investigation of electrode reaction mechanisms[J]. Electrochimica Acta,1970,15(8):1313-1324.
【3】曹楚南. 由弱极化曲线拟合估算腐蚀过程的电化学动力学参数[J]. 中国腐蚀与防护学报,1985,5(3):155-164,240.
【4】赵瑾,申忠宇. 研究弱极化区极化曲线来估算腐蚀过程的电化学动力学参数[J]. 腐蚀与防护,1998,19(2):69-72.
【5】曹楚南. 腐蚀电化学原理[M]. 2版.北京:化学工业出版社,2004:138-148.
【6】STAEHLE R W,GORMAN J A. Quantitative assessment of submodes of stress corrosion cracking on the secondary side of steam generator tubing in pressurized water reactors:part 1[J]. Corrosion,2003,59(11):931-994.
【7】孙华. 不锈钢和镍基合金在高温压水中的电化学腐蚀行为及氧化膜特征研究[D]. 沈阳:中国科学院金属研究所,2010.
【8】郦晓慧,王俭秋,韩恩厚,等. 核级商用690合金和800合金在模拟压水堆核电站一回路高温高压水中的腐蚀行为研究[J]. 金属学报,2012,48(8):941-950.
【2】BARNARTT S. Two-point and three-point methods for the investigation of electrode reaction mechanisms[J]. Electrochimica Acta,1970,15(8):1313-1324.
【3】曹楚南. 由弱极化曲线拟合估算腐蚀过程的电化学动力学参数[J]. 中国腐蚀与防护学报,1985,5(3):155-164,240.
【4】赵瑾,申忠宇. 研究弱极化区极化曲线来估算腐蚀过程的电化学动力学参数[J]. 腐蚀与防护,1998,19(2):69-72.
【5】曹楚南. 腐蚀电化学原理[M]. 2版.北京:化学工业出版社,2004:138-148.
【6】STAEHLE R W,GORMAN J A. Quantitative assessment of submodes of stress corrosion cracking on the secondary side of steam generator tubing in pressurized water reactors:part 1[J]. Corrosion,2003,59(11):931-994.
【7】孙华. 不锈钢和镍基合金在高温压水中的电化学腐蚀行为及氧化膜特征研究[D]. 沈阳:中国科学院金属研究所,2010.
【8】郦晓慧,王俭秋,韩恩厚,等. 核级商用690合金和800合金在模拟压水堆核电站一回路高温高压水中的腐蚀行为研究[J]. 金属学报,2012,48(8):941-950.