搜索热:失效分析 陶瓷
扫一扫 加微信
首页 > 期刊论文 > 论文摘要
某核电厂核级设备法兰泄漏监测管开裂原因
          
Cracking Causes of Leak Monitoring Tube of Nuclear-Grade Equipment Flange in a Nuclear Power Plant

摘    要
在国内某核电厂运行1 a后的大修期间,发现核级设备法兰泄漏监测管发生开裂。采用化学成分分析、金相检验、拉伸性能测试、扫描电镜及能谱分析等方法,分析了泄漏监测管开裂的原因。结果表明:该泄漏监测管的开裂形式为应力腐蚀开裂;泄漏监测管在安装阶段冲洗不彻底,导致氯离子残留在管内,在氯离子聚集处首先形成腐蚀坑,在应力及腐蚀性介质的共同作用下,该处产生裂纹,裂纹不断扩展,最终导致泄漏监测管发生开裂。
标    签 法兰   泄漏监测管   氯离子   腐蚀坑   应力腐蚀开裂   flange   leak monitoring tube   chloride ion   corrosion pit   stress corrosion cracking  
 
Abstract
During the overhaul period of a domestic nuclear power plant after 1 a operation, it was found that the flange leak monitoring tube of nuclear-grade equipment was cracked. The reasons for the cracking of leak monitoring tube were analyzed by chemical composition analysis, metallographic examination, tensile property test, scanning electron microscopy and energy spectrum analysis. The results showed that the cracking form of leak monitoring tube was stress corrosion cracking. During the installation stage, the flushing of leak monitoring tube was not complete, and caused chloride ions remaineing in the tube. Some corrosion pits first formed on the site of chloride ions aggregation. Under the combined action of stress and corrosive medium, cracks occurred there, and the crack continued to expand, eventually leading to leak monitoring tube cracked.

中图分类号 TG174   DOI 10.11973/fsyfh-202206018

 
  中国光学期刊网论文下载说明


所属栏目 失效分析

基金项目

收稿日期 2021/9/29

修改稿日期

网络出版日期

作者单位点击查看


引用该论文: YANG Xingwang,MA Ruoqun,XU Xinzhu. Cracking Causes of Leak Monitoring Tube of Nuclear-Grade Equipment Flange in a Nuclear Power Plant[J]. Corrosion & Protection, 2022, 43(6): 97


论文评价
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
分享论文
分享到新浪微博 分享到腾讯微博 分享到人人网 分享到 Google Reader 分享到百度搜藏分享到Twitter

参考文献
【1】LU Z,SHOJI T,MENG F,et al. Characterization of microstructure and local deformation in 316NG weld heat-affected zone and stress corrosion cracking in high temperature water[J]. Corrosion Science,2011,53(5):1916-1932.
 
【2】ANGELIU T M,ADRESEN P L,HALL E,et al. Intergranular stress corrosion cracking of unsensitized stainless steels in BWR environment[C]//Proceedings of 9th International Conference on Environmental Degradation of Materials Nuclear Power Systems-Water Reactors. Newport Beach:TMS,1999.
 
【3】杨宏亮,薛河,倪陈强.冷加工对316L不锈钢裂尖力学特性的影响[J].西安科技大学学报,2018,38(3):484-489.
 
【4】ZHOU Z X,JIN S S,LIU C L,et al. Stress Corrosion Cracking and Prevention of Austenitic Stainless Steel Pressure Pipe[J]. Physical Testing and Chemical Analysis (Part A:Physical Testing),2015,51(10):721.
 
【5】AHMED I I,GRANT B,SHERRY A H,et al. Deformation path effects on the internal stress development in cold worked austenitic steel deformed in tension[J]. Materials Science and Engineering A,2014,614(1/2):326-337.
 
【6】HOU J,SHOJI T,LU Z P,et al. Residual strain measurement and grain boundary characterization in the heat affected zone of a weld joint between alloy 690TT and alloy 52[J]. Journal of Nuclear Materials,2010,397(1/3):109-115.
 
相关信息
   标题 相关频次
 00Cr17Ni14Mo2钢法兰裂纹的产生原因
 4
 0Cr18Ni9不锈钢换热管应力腐蚀开裂原因分析
 4
 316L不锈钢在普光净化厂含氯胺液中的应力腐蚀开裂
 4
 D210塔筒体泄漏原因分析
 4
 奥氏体不锈钢法兰开裂原因分析
 4
 储气球罐连接阀螺栓断裂分析
 4
 大口径法兰开裂原因
 4
 电流互感器铝合金法兰开裂失效分析
 4
 火电厂汽轮机叶片开裂原因分析
 4
 金属波纹管补偿器的应力腐蚀开裂分析
 4
 某气田埋地管线不锈钢直角弯头开裂原因
 4
 燃机电厂304不锈钢三通管应力腐蚀开裂的原因
 4
 PTA装置碱洗对设备腐蚀开裂影响讨论
 3
 波纹管膨胀节腐蚀失效分析
 3
 加热炉不锈钢盘管泄漏失效分析
 3
 制氢装置酸性水汽提塔壁开裂的原因
 3
 1 000 MPa级超高强度热镀锌钢板耐腐蚀性能
 2
 1Cr18Ni9Ti不锈钢输油管道开裂原因分析
 2
 1Cr18Ni9Ti钢炉管开裂原因分析
 2
 2A14铝合金液压壳体开裂的原因
 2
 304不锈钢表面直流磁控溅射钛膜的耐蚀性
 2
 304不锈钢低温分离器开裂原因分析
 2
 304不锈钢在核电站二回路水环境中的应力腐蚀开裂行为
 2
 42CrMo高强度螺栓在海洋大气环境中的应力腐蚀开裂风险评估
 2
 45钢法兰调质处理开裂原因分析
 2
 500kV变电站断路器导气管接头开裂原因
 2
 60Si2MnA钢弹簧压力试验断裂原因分析
 2
 Cl-和SO42-对水冷壁管材的腐蚀影响
 2
 G105钻杆在不同氢离子浓度溶液中的腐蚀行为
 2
 GIS用不锈钢板簧断裂分析与预防
 2