Phased array ultrasonic inspection for butt fusion joint of high density polyethylene pipe in nuclear power plant
摘 要
针对HDPE (高密度聚乙烯)管道热熔接头超声检测声衰减大,检测信噪比低等问题,通过CIVA仿真软件中的超声模块对厚壁HDPE管道进行声场仿真,研究了探头频率、晶片尺寸和阵元排列对管道热熔接头中声场分布的影响,优化了检测用相控阵超声探头参数。采用优化的探头和检测工艺在含标准反射体和典型缺陷的试件上进行声场仿真和检测试验,结果表明,提出的检测工艺可全部检出φ 914.4 mm管道中预设的不同深度和类型的典型缺陷,整体检测效果较好。
Abstract
In view of the characteristics of high acoustic attenuation and low SNR of butt fusion joints in HDPE pipes, the ultrasonic module of CIVA simulation was used to simulate the sound field of thick-wall HDPE pipes. The influence of probe frequency, element size and array arrangement on the sound field distribution in butt fusion joints was studied, and the phased array probe parameters for inspection were optimized. According to the optimized probe and inspection process, the sound field simulation and inspection were carried out on the test specimen containing standard reflector and typical defects. The inspection process could detect all the typical defects of different depths and types preset in the pipes of φ 914. 4 mm.
中图分类号 TG115.28 DOI 10.11973/wsjc202306009
所属栏目 试验研究
基金项目
收稿日期 2022/11/23
修改稿日期
网络出版日期
作者单位点击查看
联系人作者甘文军(ganwj@cnpo.com)
备注甘文军(1986-),男,硕士,高级工程师,主要从事超声无损检测技术的开发工作
引用该论文: GAN Wenjun,CAI Jiafan,YAO Xiaoyuan. Phased array ultrasonic inspection for butt fusion joint of high density polyethylene pipe in nuclear power plant[J]. Nondestructive Testing, 2023, 45(6): 43~48
甘文军,蔡家藩,姚晓园. 核级高密度聚乙烯管道热熔接头的相控阵超声检测[J]. 无损检测, 2023, 45(6): 43~48
共有人对该论文发表了看法,其中:
人认为该论文很差
人认为该论文较差
人认为该论文一般
人认为该论文较好
人认为该论文很好
参考文献
【1】孙海涛, 凌礼恭, 陈树山, 等. 核电厂核级高密度聚乙烯管道应用技术要求[J]. 中国塑料, 2021, 35(4):93-97.
【2】周路生, 黄骄, 吴双, 等. 核电厂厚壁高密度聚乙烯管道热熔接头的相控阵超声检测[J]. 无损检测, 2022, 44(1):10-15.
【3】王少军, 裘爱东, 宋盼, 等. 埋地聚乙烯管道热熔接头的超声相控阵检测[J]. 无损检测, 2017, 39(5):21-23.
【2】周路生, 黄骄, 吴双, 等. 核电厂厚壁高密度聚乙烯管道热熔接头的相控阵超声检测[J]. 无损检测, 2022, 44(1):10-15.
【3】王少军, 裘爱东, 宋盼, 等. 埋地聚乙烯管道热熔接头的超声相控阵检测[J]. 无损检测, 2017, 39(5):21-23.
相关信息