ZHU Lei, FANG Zhi-ming, WANG Zhuo-lin, ZHU Bin, JIANG Li-xue, XU Qing-feng. Inspection and Assessment of the Defects of Exterior Walls Cement Coating[J]. Nondestructive Testing, 2016, 38(6): 10-16. DOI: 10.11973/wsjc201606003
Citation: ZHU Lei, FANG Zhi-ming, WANG Zhuo-lin, ZHU Bin, JIANG Li-xue, XU Qing-feng. Inspection and Assessment of the Defects of Exterior Walls Cement Coating[J]. Nondestructive Testing, 2016, 38(6): 10-16. DOI: 10.11973/wsjc201606003

Inspection and Assessment of the Defects of Exterior Walls Cement Coating

More Information
  • Received Date: July 10, 2015
  • Infrared thermography method was used to inspect the defects of exterior walls cement coating under different environmental conditions. The effects of weather conditions, test time in a day and outdoor temperatures on the test results were analyzed, and the suitable conditions in the current technical specifications for defects inspection of exterior walls cement coating using infrared thermography method were modified. The experimental results showed that, the defects of small size were easily to be omitted by mistake in a cloudy day or when the outdoor temperature was lower than 10℃. The method for evaluating the area of bonding defects was proposed based on the image processing of infrared thermography method. The proposed method was effective and quantitative for extracting the area of exfoliation of cement coating. The image processing analysis results showed that, the inspecting result of infrared thermography method was better when at higher outdoor temperature, with larger area and more shallow depth of exfoliation of cement coating. The effect of the thickness of exfoliation of cement coating was not obvious on the inspecting result of infrared thermography method.
  • [1]
    DATCU S, IBOS L, CANDAU Y, et al. Improvement of building wall surface temperature measurements by infrared thermography[J]. Infrared Physics & Technology, 2005, 46(6): 451-467.
    [2]
    MAHABOONPACHAI T, KUROMIYA Y, MATSUMOTO T. Experimental investigation of adhesion failure of the interface between concrete and polymer-cement mortar in an external wall tile structure under a thermal load[J]. Construction and Building Materials, 2008, 22(9): 2001-2006.
    [3]
    张荣成. 红外热像法检测建筑物外墙饰面施工质量的试验研究[J]. 建筑科学, 2002, 18(1): 40-44.
    [4]
    袁昕, 谢慧才, 陈高峰. 建筑物外墙饰面砖粘贴质量的红外热像检测试验研究[J]. 四川建筑科学研究, 2003, 29(2): 43-45.
    [5]
    冯力强, 王欢祥, 晏大玮, 等. 红外热像法检测建筑外墙饰面层内部缺陷试验研究[J]. 土木工程学报, 2014, 47(6): 51-56.
    [6]
    EDIS E, FLORES-COLEN I, DE BRITO J. Passive thermographic inspection of adhered ceramic claddings: limitation and conditioning factors[J]. Journal of Performance of Constructed Facilities, 2012, 27(6): 737-747.
    [7]
    张德芳. 红外热像法检测外墙饰面空鼓缺陷时结果的可靠性[J]. 工程质量, 2013, 30(11): 73-75.
    [8]
    李芸, 刘永福, 周宏, 等. 红外热像法检测外墙饰面砖黏结缺陷的应用研究[J]. 住宅科技, 2014, 34(1): 52-54.
    [9]
    ABDEL-AZIZ Y I, KARARA H M. Direct linear transformation from comparator coordinates into object space coordinates[C]∥Proceedings of the ASP Symposium on Close-Range Photogrammetry. Falls Church, VA: American Society of Photogrammetry, 1971:1-18.
    [10]
    OSTU N. A threshold selection method from gray-level histograms[J]. IEEE Trans, 1979, SMC-9: 62-66.